Info >> Special Offers >>> Raybiotech Cytokinedetection

 

24.Mai 2006 - Mutiple Cytokinedetection der Firma Raybiotech NEU!

RayBio® Human Cytokine QuantibodyTM Arrays

* eine neue Methode zur Bestimmung von 10 Cytokinen aus nur 1 Probe.

* mittels der Slidetechnology ( sehr einfache Auswertung! ) und dem Fluoreszenznachweis können aus 8 - 15 Proben jeweils 10 Parameter quantifiziert werden.


die folgenden Arrays stehen zur Verfügung:

Raybio® Human Cytokine Quantibody™ TH1/TH2 Array 1

( IL-2, IL-4, IL-5, IL-6, IL-8, IL-10, IL-13, GM-CSF, IFN-gamma, TNF-alpha)
Bestellnr: QAH-TH-1-1 / QAH-TH-1-2

Raybio® Human Cytokine Quantibody™ Inflammation Array 1

( IL-1a, IL-1ß, IL-4, IL-6, IL-8, IL-10, IL-13, MCP-1, IFN-gamma, TNF-alpha)
Bestellnr: QAH-INF-1-1 / QAH-INF-1-2


Originalinformation von Raybiotech:

RayBio® Human Cytokine QuantibodyTM Arrays
-Measure the concentration of 10 cytokines in a single experiment


Raybio® Human Cytokine Quantibody™ TH1/TH2 Array 1
( IL-2, IL-4, IL-5, IL-6, IL-8, IL-10, IL-13, GM-CSF, IFN-gamma, TNF-alpha)
Raybio® Human Cytokine Quantibody™ Inflammation Array 1
( IL-1a, IL-1ß, IL-4, IL-6, IL-8, IL-10, IL-13, MCP-1, IFN-gamma, TNF-alpha)

      In addition to its matchless high-density cytokine antibody arrays, Raybiotech Inc. is now proudly offering the Quantibody™ products for simultaneous quantitative measurement of multiple cytokines. The kit can be used for diverse sample types: serum, plasma, cell lysate, conditioned media and other body fluid.
      Our human cytokine Quantibody ™ Arrays use fluorescent detection method, which increase the signal reproducibility and accuracy than chemiluminescent and colorimetric platforms. After blocking arrays with blocking buffer, the arrays are incubated with samples. Unspecific bound proteins are then removed and the arrays are incubated with a cocktail of biotin-antibodies and then streptavidin-conjugated Alexa Fluor 555. The signal can be detected with most of the microarray laser scanners.
      Sixteen identical antibody arrays are spotted on a piece of standard glass slide using a non-contact arrayer. Each of the 10-cytokine specific capture antibody is arrayed in quadruplicate, together with positive and negative controls. Cytokine standards, whose concentration has been predetermined and calibrated with international reference standards, were provided to generate a five-point standard curve of the 10 cytokines. In a real experiment, standard cytokines and samples will be assayed in each array simultaneously through a sandwich ELISA procedure. By comparing signals from unknown samples to the standard curve, the unknown cytokine concentration in the samples will be determined.

      The product comes with a 16-well removable gasket to form a modular device. You can measure 10 different cytokines in quadruplicate from up to 16 samples per slide within 4 hours. Four modules can be nested into a tray, which matches a standard microplate and allows for automated robotic high throughput process of 64 arrays simultaneously. As little as 50-µl samples per well is required to generate 48 times more data than traditional ELISA, especially precious when sample supply is limited. Also, the cost per sample data point is only a fraction of the cost of traditional ELISA.
      High affinity antibodies were used in our product. Each antibody pair has been optimized for its highest sensitivity, as low as 5 pg/ml.
      We also provide custom testing services. You can simply send us your samples and we will do all assays for you.

  Format: Standard glass slide with 16 removable wells
Sample Volume: 50-100 ul
Detection Range: 5-3000 pg/ml Standard Curve Range: 5-800 pg/ml
Signal Duration: 4 hours Reproducibility: <20% well-to-well CV
Detection Method: Fluorescence. Alexa Fluor 555 (Cy3 wavelengths 555 nm excitation, 655 emission) 

PRODUCT UNIT CAT #
Raybio® Human Cytokine Quantibody™ TH1/TH2 Array 1    (IL-2, IL-4, IL-5, IL-6, IL-8, IL-10, IL-13, GM-CSF, IFN-alpha, TNF-gamma) 1 slide QAH-TH-1-1
2 slide QAH-TH-1-2
Software QAH-TH-1-SW
     
Raybio® Human Cytokine Quantibody™ Inflammation Array 1    (IL-1a, IL-1ß, IL-4, IL-6, IL-8, IL-10, IL-13, MCP-1, IFN-alpha, TNF-gamma) 1 slide QAH-INF-1-1
2 slide QAH-INF-1-2
Software QAH-INF-1-SW

 

 