Hersteller |
Abbkine Scientific
|
Kategorie |
|
Typ |
Elisa-Kit |
Specific against |
Mouse |
Applikationen |
ELISA |
Menge |
48T |
ArtNr |
ABK-KTE70150-48T |
eClass 6.1 |
32160605 |
eClass 9.0 |
32160605 |
Lieferbar |
|
Applications notes |
This Mouse Transmembrane protease serine 4 (TMPRSS4) ELISA Kit employs a two-site sandwich ELISA to quantitate TMPRSS4 in samples. An antibody specific for TMPRSS4 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and anyTMPRSS4 present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for TMPRSS4 is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of TMPRSS4 bound in the initial step. The color development is stopped and the intensity of the color is measured. |
Detection method |
Colorimetric |
Sample type |
Cell culture supernatants#Serum#Plasma#Other biological fluids |
Assay type |
Sandwich ELISA (quantitative) |
Assay duration |
Multiple steps standard sandwich ELISA assay with a working time of 3-5 hours. It depends on the experience of the operation person. |
Kit components |
Mouse Transmembrane protease serine 4 microplate Mouse Transmembrane protease serine 4 standard Mouse Transmembrane protease serine 4 detect antibody Streptavidin-HRP Standard diluent Assay buffer HRP substrate Stop solution Wash buffer Plate covers |
Features & Benefits |
Mouse Transmembrane protease serine 4 (TMPRSS4) ELISA Kit has high sensitivity and excellent specificity for detection of Mouse TMPRSS4. No significant cross-reactivity or interference between Mouse TMPRSS4 and analogues was observed. |
Usage notes |
Do not mix components from different kit lots or use reagents beyond the kit expiration date. Allow all reagents to warm to room temperature for at least 30 minutes before opening. Pre-rinse the pipet tip with reagent, use fresh pipet tips for each sample, standard and reagent to avoid contamination. Unused wells must be kept desiccated at 4 C in the sealed bag provided. Mix Thoroughly is very important for the result. It is recommended using low frequency oscillator or slight hand shaking every 10 minutes. It is recommended that all samples and standards be assayed in duplicate or triplicate. |
Storage instructions |
The unopened kit should be stored at 2 - 8C. After opening, please store refer to protocols. |
Shipping |
Gel pack with blue ice. |
Precautions |
The product listed herein is for research use only and is not intended for use in human or clinical diagnosis. Suggested applications of our products are not recommendations to use our products in violation of any patent or as a license. We cannot be responsible for patent infringements or other violations that may occur with the use of this product. |
Background |
TMPRSS4 encodes a member of the serine protease family. Serine proteases are known to be involved in a variety of biological processes, whose malfunction often leads to human diseases and disorders. This gene was identified as a gene overexpressed in pancreatic carcinoma. The encoded protein is membrane bound with a N-terminal anchor sequence and a glycosylated extracellular region containing the serine protease domain. Multiple transcript variants encoding different isoforms have been found for this gene.A weak TMPRSS4 signal was detected in normal tissues of the gastrointestinal tract and in some of the urogenital tract but was not expressed in any other normal tissues. The authors suggested that TMPRSS4 may be important in processes involved in metastasis formation and tumor invasion. |
Gene ID |
214523 |
Alternative |
TMPRSS4; MT-SP2; TMPRSS3; membrane-type serine protease 2; transmembrane serine protease 3; type membrane serine protease |
Accession |
Q8VCA5 |
Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.
Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.