ELISA Kit for Cluster Of Differentiation 40 Ligand (CD40L)

Hersteller Cloud-Clone
Kategorie
Typ Elisa-Kit
Specific against Mouse
Applikationen ELISA
Menge 48T
ArtNr SEA119Mu-48
eClass 6.1 32160605
eClass 9.0 32160605
Lieferbar
Target Name
Cluster Of Differentiation 40 Ligand
Alternative Names
CD154, TRAP, HIGM1, IGM, IMD3, TBAM, T-BAM, TNFSF5, Gp39, TNF Superfamily Member 5, Hyper-IgM Syndrome, TNF-Related Activation Protein, T-Cell B-Cell Activating Molecule
Uniprot
P27548
Detection range
15.6-1, 000pg/mL
Application info
Enzyme-linked immunosorbent assay for Antigen Detection.
Sensitivity
<6.7pg/mL
Sample type
Serum, plasma, tissue homogenates, cell lysates and other biological fluids
Assay length
3h
Method
Double-antibody Sandwich
Specificity
This assay has high sensitivity and excellent specificity for detection of Cluster Of Differentiation 40 Ligand (CD40L).
No significant cross-reactivity or interference between Cluster Of Differentiation 40 Ligand (CD40L) and analogues was observed.
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cluster Of Differentiation 40 Ligand (CD40L) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cluster Of Differentiation 40 Ligand (CD40L) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary
1.Prepareallreagents, samplesandstandards;
2.Add100µ Lstandardorsampletoeachwell.Incubate2hoursat37° C;
3.Aspirateandadd100µ LpreparedDetectionReagentA.Incubate1hourat37° C;
4.Aspirateandwash3times;
5.Add100µ LpreparedDetectionReagentB.Incubate30minutesat37° C;
6.Aspirateandwash5times;
7.Add90µ LSubstrateSolution.Incubate10-20minutesat37° C;
8.Add50µ LStopSolution.Readat450nmimmediately.
Test principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Cluster Of Differentiation 40 Ligand (CD40L). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Cluster Of Differentiation 40 Ligand (CD40L). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Cluster Of Differentiation 40 Ligand (CD40L), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Cluster Of Differentiation 40 Ligand (CD40L) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Research Area
Signal transduction, CD & Adhesion molecule, Apoptosis, Tumor immunity, Infection immunity, Immune molecule,
References
The Protective Effects of Alisol A 24-Acetate from Alisma canaliculatum on Ovariectomy Induced Bone Loss in Vivo
Effects of diisononyl phthalate on osteopenia in intact mice

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt und Sicherheitsdatenblatt) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Menge: 48T
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen