ELISA Kit for Tissue Inhibitors Of Metalloproteinase 3 (TIMP3)

Hersteller Cloud-Clone
Kategorie
Typ Elisa-Kit
Specific against Mouse
Applikationen ELISA
Menge 10x96T
ArtNr SEA129Mu-10
eClass 6.1 32160605
eClass 9.0 32160605
Lieferbar
Target Name
Tissue Inhibitors Of Metalloproteinase 3
Alternative Names
SFD, TIMP Metallopeptidase Inhibitor 3, Metallopeptidase Inhibitor 3, Sorsby Fundus Dystrophy, Pseudoinflammatory
Uniprot
P39876
Detection range
0.156-10ng/mL
Application info
Enzyme-linked immunosorbent assay for Antigen Detection.
Sensitivity
<0.055ng/mL
Sample type
Serum, plasma, tissue homogenates and other biological fluids
Assay length
3h
Method
Double-antibody Sandwich
Specificity
This assay has high sensitivity and excellent specificity for detection of Tissue Inhibitors Of Metalloproteinase 3 (TIMP3).
No significant cross-reactivity or interference between Tissue Inhibitors Of Metalloproteinase 3 (TIMP3) and analogues was observed.
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Tissue Inhibitors Of Metalloproteinase 3 (TIMP3) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Tissue Inhibitors Of Metalloproteinase 3 (TIMP3) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary
1.Prepareallreagents, samplesandstandards;
2.Add100µ Lstandardorsampletoeachwell.Incubate2hoursat37° C;
3.Aspirateandadd100µ LpreparedDetectionReagentA.Incubate1hourat37° C;
4.Aspirateandwash3times;
5.Add100µ LpreparedDetectionReagentB.Incubate30minutesat37° C;
6.Aspirateandwash5times;
7.Add90µ LSubstrateSolution.Incubate10-20minutesat37° C;
8.Add50µ LStopSolution.Readat450nmimmediately.
Test principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Tissue Inhibitors Of Metalloproteinase 3 (TIMP3). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Tissue Inhibitors Of Metalloproteinase 3 (TIMP3). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Tissue Inhibitors Of Metalloproteinase 3 (TIMP3), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Tissue Inhibitors Of Metalloproteinase 3 (TIMP3) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Research Area
Tumor immunity, Cardiovascular biology,
References
Upregulated Expression of Matrix Metalloproteinases and Tissue Inhibitors of Matrix Metalloproteinases in BALB/c Mouse Brain Challenged with Japanese Encephalitis Virus
Circulating levels of matrix metalloproteinases and tissue inhibitors of matrix metalloproteinases during Japanese encephalitis virus infection

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt und Sicherheitsdatenblatt) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Menge: 10x96T
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen