Vergleich

Human Metanephrine (MN) ELISA Kit

Hersteller Abbkine Scientific
Kategorie
Typ Elisa-Kit
Specific against Human
Applikationen ELISA
Menge 96Tx50
ArtNr ABK-KTE62576-96Tx50
eClass 6.1 32160605
eClass 9.0 32160605
Lieferbar
Applications notes
This Human Metanephrine (MN) ELISA Kit employs a two-site sandwich ELISA to quantitate MN in samples. An antibody specific for MN has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and anyMN present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for MN is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of MN bound in the initial step. The color development is stopped and the intensity of the color is measured.
Detection method
Colorimetric
Sample type
Cell culture supernatants#Serum#Plasma#Other biological fluids
Assay type
Sandwich ELISA (quantitative)
Assay duration
Multiple steps standard sandwich ELISA assay with a working time of 3-5 hours. It depends on the experience of the operation person.
Kit components

Human Metanephrine microplate
Human Metanephrine standard
Human Metanephrine detect antibody
Streptavidin-HRP
Standard diluent
Assay buffer
HRP substrate
Stop solution
Wash buffer
Plate covers
Features & Benefits
Human Metanephrine (MN) ELISA Kit has high sensitivity and excellent specificity for detection of Human MN. No significant cross-reactivity or interference between Human MN and analogues was observed.
Usage notes
Do not mix components from different kit lots or use reagents beyond the kit expiration date.
Allow all reagents to warm to room temperature for at least 30 minutes before opening.
Pre-rinse the pipet tip with reagent, use fresh pipet tips for each sample, standard and reagent to avoid contamination.
Unused wells must be kept desiccated at 4 C in the sealed bag provided.
Mix Thoroughly is very important for the result. It is recommended using low frequency oscillator or slight hand shaking every 10 minutes.
It is recommended that all samples and standards be assayed in duplicate or triplicate.
Storage instructions
The unopened kit should be stored at 2 - 8C. After opening, please store refer to protocols.
Shipping
Gel pack with blue ice.
Precautions
The product listed herein is for research use only and is not intended for use in human or clinical diagnosis. Suggested applications of our products are not recommendations to use our products in violation of any patent or as a license. We cannot be responsible for patent infringements or other violations that may occur with the use of this product.
Background
Metanephrine is a metabolite of epinephrine created by action of catechol-O-methyl transferase on epinephrine. A March 20, 2002 article in the Journal of the American Medical Association indicated that the measurement of plasma free metanephrines is the best tool in the diagnosis of pheochromocytoma, an adrenal medullary neoplasm.Product of epinephrine O-methylation. It is a commonly occurring, pharmacologically and physiologically inactive metabolite of epinephrine. Several clinical disorders mimic the signs and symptoms of pheochromocytoma; the definitive diagnosis of this condition thus rests primarily on showing excessive and inappropriate production of catecholamine. Because pheochromocytoma is fatal if undiagnosed, biochemical tests used to detect it should have a high sensitivity. In addition, the predictive value of any negative test result should exclude false-negative results as efficiently as possible.
Alternative
MN

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 96Tx50
Lieferbar: In stock
lieferbar

Lieferung vsl. bis 13.06.2024 

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen