Vergleich

Anti-AT2 Receptor (ext.)-ATTO Fluor-488 Europäischer Partner

ArtNr ALO-AAR-012-AG-50ul
Hersteller Alomone
Menge 50 ul
Kategorie
Typ Antibody Polyclonal
Format Lyophilized
Applikationen IF, IHC, IC
Specific against Human (Homo sapiens), Mouse (Murine, Mus musculus), Rat (Rattus norvegicus)
Host Rabbit
Isotype IgG
Konjugat/Tag ATTO 488, FITC
Purity Affinity purified on immobilized antigen.
Formula PBS pH7.4, 1% BSA with 0.05% sodium azide
Sequence DNLNATGTNESAFNC, corresponding to amino acid residues 21-35 of rat AT2 receptor
ECLASS 10.1 32160702
ECLASS 11.0 32160702
UNSPSC 12352203
Versandbedingung Raumtemperatur
Lieferbar
Specificity Polyclonal
Manufacturer - Type
Antibodies
Manufacturer - Category
Antibodies
Manufacturer - Targets
AT2 Receptor, AT2R, AGTR2, MRX88
Manufacturer - Conjugate / Tag
ATTO-488. Maximum absorption 501 nm; maximum fluorescence 523 nm. The fluorescence is excited most efficiently in the 480 - 515 nm range. This label is analogous to the dye fluorescein isothiocyanate (FITC) and can be used with filters used to detect FITC.
Country of Origin
Israel
Shipping Temperature
Shipped at room temperature. Product as supplied can be stored intact at room temperature for several weeks. For longer periods, it should be stored at -20°C
Storage Conditions
Storage before Reconstitution: The antibody ships as a lyophilized powder at room temperature. Upon arrival, it should be stored at -20°C - Storage after Reconstitution: The reconstituted solution can be stored at 4°C, protected from the light, for up to 1 week. For longer periods, small aliquots should be stored at -20°C. Avoid multiple freezing and thawing. Centrifuge all antibody preparations before use (10000 x g 5 min).
Manufacturer - Format
Lyophilized powder
Short description
A Rabbit Polyclonal Antibody to Angiotensin II Receptor Type-2 Conjugated to the Fluorescent Dye ATTO-488
Description
AT2 Receptor, AT2R, AGTR2, MRX88 - A Rabbit Polyclonal Antibody to Angiotensin II Receptor Type-2 Conjugated to the Fluorescent Dye ATTO-488
Clonality
Polyclonal
Homology
Mouse - identical
Standard quality control of each lot
Western blot analysis (unlabeled antibody, #AAR-012), and immunohistochemistry (labeled antibody).
Peptide confirmation
Confirmed by amino acid analysis and mass spectrometry
Reconstitution
50 µl double distilled water (DDW).
Antibody Concentration After Reconstitution
1 mg/ml
Preservative
1% BSA, 0.05% NaN3
Immunogen Location
Extracellular, N-terminal domain
Specificity
AGTR2
AB - Specificity
Will not recognize human AT2 Receptor.
Immunogen source species
Rat
PH
7, 4
UNSPSC
41116161
Ko Validate
yes
Antigen Preadsorption Control
1 µg peptide per 1 µg antibody
Scientific Background
Angiotensin II receptor type 2 or AT2 is one of the receptors that bind the octapeptide hormone Angiotensin II (Ang II). Ang II is the peptide hormone that generates most of the known effects of the renin-angiotensin system (RAS). Ang II is generated from the angiotensinogen protein by the actions of renin, angiotensin converting enzyme (ACE) and other peptidases. Ang II has a central role in cardiovascular homeostasis by regulating vasoconstriction, renal Na+ and water readsorption. In addition, Ang II induces cell growth and proliferation and has pro-inflammatory effects. Most of the physiological actions of Ang II are mediated by AT1 a member of the 7-transmembrane domain, G protein-coupled receptor (GPCR) superfamily. AT2 is also a GPCR, and is largely believed to have counter-regulatory roles to the ones exerted through the AT1 receptor. Hence, binding of Ang II to the AT2 receptor will result in growth arrest and apoptosis, vasodilatation and hypotension. Although the AT2 receptor is structurally a member of the GPCR superfamily, the signaling mechanisms elicited following AT2 receptor activation are not fully clarified. Recent evidence indicates that the AT2 receptor signals through the Giα2 and the Giα3 proteins and through the activation of phosphotyrosine phosphatases such as SHP-1. AT2 receptor distribution is more restricted than that of the AT1 receptor. The highest expression levels of AT2 have been found in the fetus, which is followed by a marked decrease shortly after birth. Nevertheless, significant AT2 receptor expression can be detected in the heart, kidney, vascular endothelial cells and brain, among others.

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 50 ul
Lieferbar: In stock
lieferbar

Lieferung vsl. bis 04.12.2025 

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen