Vergleich

MYOC ELISA Kit (Human)

ArtNr OKCD01267
Hersteller AVIVA Systems Biology
Menge 96 Wells
Kategorie
Typ Elisa-Kit
Applikationen ELISA
Specific against Human (Homo sapiens)
Sensitivity < 0.26 ng/mL
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias GLC1A;GPOA;JOAG;JOAG1;juvenile-onset open-angle glaucoma 1;mutated trabecular meshwork-induced glucocorticoid response protein;myocilin;myocilin 55 kDa subunit;myocilin trabecular meshwork inducible glucocorticoid response protein;TIGR;trabecular meshwork inducible glucocorticoid response protein;Trabecular meshwork-induced glucocorticoid response protein.
Versandbedingung Gekühlt
Lieferbar
Manufacturer - Type
ELISA Kit
Manufacturer - Applications
Enzyme-linked Immunosorbent assay-Sandwich
Manufacturer - Category
Root Catalog/Products/ELISA Kits, Root Catalog/Products/Kit
Shipping Temperature
Wet Ice
Gene symbol
MYOC
Gene Fullname
myocilin
Protein size
504
Reconstitution and storage
2°C to 8°C|-20°C
Description of target
Secreted glycoprotein regulating the activation of different signaling pathways in adjacent cells to control different processes including cell adhesion, cell-matrix adhesion, cytoskeleton organization and cell migration. Promotes substrate adhesion, spreading and formation of focal contacts. Negatively regulates cell-matrix adhesion and stress fiber assembly through Rho protein signal transduction. Modulates the organization of actin cytoskeleton by stimulating the formation of stress fibers through interactions with components of Wnt signaling pathways. Promotes cell migration through activation of PTK2 and the downstream phosphatidylinositol 3-kinase signaling. Plays a role in bone formation and promotes osteoblast differentiation in a dose-dependent manner through mitogen-activated protein kinase signaling. Mediates myelination in the peripheral nervous system through ERBB2/ERBB3 signaling. Plays a role as a regulator of muscle hypertrophy through the components of dystrophin-associated protein complex. Involved in positive regulation of mitochondrial depolarization. Plays a role in neurite outgrowth. May participate in the obstruction of fluid outflow in the trabecular meshwork.
Nucleotide accession_num
NM_000261.1
Protein accession_num
NP_000252
Protein name
Myocilin
Manufacturer - Specificity
This assay has high sensitivity and excellent specificity for detection of Myocilin (MYOC).No significant cross-reactivity or interference between Myocilin (MYOC) and analogues was observed.
Assay info
Assay Methodology: Quantitative Sandwich Immunoassay
Kit Components
Component: Amount
Anti-MYOC Microplate: 96 Wells (12 x 8 Well Strips)
MYOC Lyophilized Standard: 2 x 50 ng
100X Biotinylated MYOC Detector Antibody: 120 uL
Avidin/HRP Conjugate: 120 uL
Standard Diluent: 1 x 20 mL
Detector Antibody Diluent: 1 x 12 mL
Conjugate Diluent: 1 x 12 mL
30X Wash Buffer: 1 x 20 mL
TMB Substrate: 1 x 9 mL
Stop Solution: 1 x 6 mL
Kit detection
Colorimetric
Kit duration
3h
Kit principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Myocilin (MYOC). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Myocilin (MYOC). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Myocilin (MYOC), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of Myocilin (MYOC) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Kit reproducibility
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Myocilin (MYOC) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Myocilin (MYOC) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
Sample Type
Tissue homogenates and other biological fluids.

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 96 Wells
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen