Insulin Auto-antibody ELISA Kit (Human)

ArtNr OKCD01296
Hersteller AVIVA Systems Biology
Menge 96 Wells
Kategorie
Typ Elisa-Kit
Applikationen ELISA
Specific against Human (Homo sapiens)
Sensitivity 1.15 ng/mL
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias INSR,IDDM2,ILPR,Insulin,IRDN,MODY10
Versandbedingung Gekühlt
Lieferbar
Manufacturer - Type
ELISA Kit
Manufacturer - Applications
Enzyme-linked Immunosorbent assay-Competitive
Manufacturer - Category
Root Catalog/Products/ELISA Kits, Root Catalog/Products/Kit
Shipping Temperature
Wet Ice
Reconstitution and storage
2°C to 8°C|-20°C
Description of target
Insulin Auto-antibody
Nucleotide accession_num
NM_000207.2
Protein name
Insulin Autoantibody
Assay info
Assay Method: Quantitative Reverse Capture Sandwich ELISA
Kit Components
Component: Amount
Insulin Auto-antibody Microplate: 96 Wells (12 x 8 Well strips)
Insulin Auto-antibody Lyophilized Standard: 2 x XXX
100X Detector Antibody: 1 x 120 uL
Standard Diluent: 1 x 20 mL
Detector Antibody Diluent: 1 x 12 mL
30X Wash Buffer: 1 x 20 mL
Stop Solution: 1 x 6 mL
TMB Substrate: 1 x 9 mL
Kit detection
Colorimetric
Kit duration
2h, 30min
Kit linearity
Sample - 1:2 - 1:4 - 1:8 - 1:16
Serum (n=5) - 96-105% - 96-103% - 95-102% - 88-101%
EDTA Plasma (n=5) - 79-93% - 81-101% - 91-99% - 95-103%
Heparin Plasma (n=5) - 96-105% - 78-99% - 87-96% - 94-101%
Kit principle
The microtiter plate provided in this kit has been pre-coated with an antigen. Standards or samples are then added to the appropriate microtiter plate wells with a Horseradish Peroxidase (HRP)-conjugated secondary antibody. After TMB substrate solution is added, those wells that contain Insulin Autoantibody (IAA) will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of Insulin Autoantibody (IAA) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Kit recovery
Matrix - Recovery range (%) - Average(%)
Serum (n=5) - 98-105 - 102
EDTA Plasma (n=5) - 83-96 - 86
Heparin Plasma (n=5) - 92-103 - 99
Kit reproducibility
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Insulin Autoantibody (IAA) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Insulin Autoantibody (IAA) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
Sample Type
Serum, plasma and other biological fluids

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 96 Wells
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen