Vergleich

HP High Sensitivity ELISA Kit (Human)

ArtNr OKCD01336
Hersteller AVIVA Systems Biology
Menge 96 Wells
Kategorie
Typ Elisa-Kit
Applikationen ELISA
Specific against Human (Homo sapiens)
Sensitivity 0.102 ng/mL
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias binding peptide;BP;haptoglobin;haptoglobin alpha(1S)-beta;haptoglobin alpha(2FS)-beta;haptoglobin,alpha polypeptide;haptoglobin,beta polypeptide;HP2ALPHA2;HPA1S;zonulin.
Versandbedingung Gekühlt
Lieferbar
Manufacturer - Type
ELISA Kit
Manufacturer - Applications
Enzyme-linked Immunosorbent assay-Sandwich
Manufacturer - Category
Root Catalog/Products/ELISA Kits, Root Catalog/Products/Kit
Shipping Temperature
Wet Ice
Gene symbol
HP
Gene Fullname
haptoglobin
Reconstitution and storage
2°C to 8°C|-20°C
Description of target
As a result of hemolysis, hemoglobin is found to accumulate in the kidney and is secreted in the urine. Haptoglobin captures, and combines with free plasma hemoglobin to allow hepatic recycling of heme iron and to prevent kidney damage. Haptoglobin also acts as an Antimicrobial; Antioxidant, has antibacterial activity and plays a role in modulating many aspects of the acute phase response. Hemoglobin/haptoglobin complexes are rapidely cleared by the macrophage CD163 scavenger receptor expressed on the surface of liver Kupfer cells through an endocytic lysosomal degradation pathway.
Nucleotide accession_num
NM_001126102.2
Protein accession_num
NP_001119574.1
Protein name
Haptoglobin
Manufacturer - Specificity
This assay has high sensitivity and excellent specificity for detection of Haptoglobin (Hpt). No significant cross-reactivity or interference between Haptoglobin (Hpt) and analogues was observed.
Assay info
Assay Methodology: Quantitative Sandwich ELISA
Kit Components
Component: Amount
Anti-HP Microplate: 96 Wells (12 x 8 Well Strips)
HP Lyophilized Standard: 2
100X Biotinylated HP Detector Antibody: 120 uL
Avidin/HRP Conjugate: 120 uL
Standard Diluent: 1 x 20 mL
Detector Antibody Diluent: 1 x 12 mL
Conjugate Diluent: 1 x 12 mL
30X Wash Buffer: 1 x 20 mL
TMB Substrate: 1 x 9 mL
Stop Solution: 1 x 6 mL
Kit detection
Colorimetric
Kit duration
3h
Kit linearity
Sample - 1:2 - 1:4 - 1:8 - 1:16
Serum (n=5) - 86-103% - 83-90% - 97-104% - 92-99%
EDTA Plasma (n=5) - 87-95% - 85-99% - 88-99% - 95-103%
Heparin Plasma (n=5) - 86-95% - 95-102% - 91-99% - 90-104%
Kit principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to High Sensitive Haptoglobin (Hpt). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to High Sensitive Haptoglobin (Hpt). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain High Sensitive Haptoglobin (Hpt), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of High Sensitive Haptoglobin (Hpt) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Kit recovery
Matrix - Recovery range (%) - Average(%)
Serum (n=5) - 78-97 - 93
EDTA Plasma (n=5) - 78-92 - 80
Heparin Plasma (n=5) - 98-105 - 101
Kit reproducibility
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Sensitive Haptoglobin (Hpt) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Sensitive Haptoglobin (Hpt) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
Sample Type
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 96 Wells
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen