Vergleich

EGLN1 ELISA Kit (Human)

ArtNr OKCD02054
Hersteller AVIVA Systems Biology
Menge 96 Wells
Kategorie
Typ Elisa-Kit
Applikationen ELISA
Specific against Human (Homo sapiens)
Sensitivity < 12.2 pg/mL
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias C1orf12;ECYT3;egl nine homolog 1;egl nine-like protein 1;HALAH;HIFPH2;HIF-PH2;HIF-prolyl hydroxylase 2;HPH2;HPH-2;hypoxia-inducible factor prolyl hydroxylase 2;PHD2;prolyl hydroxylase domain-containing protein 2;SM20;SM-20;zinc finger MYND domain-containing protein 6;ZMYND6.
Versandbedingung Gekühlt
Lieferbar
Manufacturer - Type
ELISA Kit
Manufacturer - Applications
Enzyme-linked Immunosorbent assay-Sandwich
Manufacturer - Category
Root Catalog/Products/ELISA Kits, Root Catalog/Products/Kit
Shipping Temperature
Wet Ice
Gene symbol
EGLN1
Gene Fullname
egl-9 family hypoxia inducible factor 1
Protein size
426
Reconstitution and storage
2°C to 8°C|-20°C
Description of target
Cellular oxygen sensor that catalyzes, under normoxic conditions, the post-translational formation of 4-hydroxyproline in hypoxia-inducible factor (HIF) alpha proteins. Hydroxylates a specific proline found in each of the oxygen-dependent degradation (ODD) domains (N-terminal, NODD, and C-terminal, CODD) of HIF1A. Also hydroxylates HIF2A. Has a preference for the CODD site for both HIF1A and HIF1B. Hydroxylated HIFs are then targeted for proteasomal degradation via the von Hippel-Lindau ubiquitination complex. Under hypoxic conditions, the hydroxylation reaction is attenuated allowing HIFs to escape degradation resulting in their translocation to the nucleus, heterodimerization with HIF1B, and increased expression of hypoxy-inducible genes. EGLN1 is the most important isozyme under normoxia and, through regulating the stability of HIF1, involved in various hypoxia-influenced processes such as angiogenesis in retinal and cardiac functionality. Target proteins are preferentially recognized via a LXXLAP motif.
Nucleotide accession_num
NM_022051.2
Protein accession_num
NP_071334.1
Protein name
Egl nine homolog 1
Manufacturer - Specificity
This assay has high sensitivity and excellent specificity for detection of Egl Nine Homolog 1 (EGLN1). No significant cross-reactivity or interference between Egl Nine Homolog 1 (EGLN1) and analogues was observed.
Assay info
Assay Methodology: Quantitative Sandwich Immunoassay
Kit Components
Component: Amount
Anti-EGLN1 Microplate: 96 Wells (12 x 8 Well Strips)
EGLN1 Lyophilized Standard: 2 x 2 ng
100X Biotinylated EGLN1 Detector Antibody: 120 uL
Avidin/HRP Conjugate: 120 uL
Standard Diluent: 1 x 20 mL
Detector Antibody Diluent: 1 x 12 mL
Conjugate Diluent: 1 x 12 mL
30X Wash Buffer: 1 x 20 mL
TMB Substrate: 1 x 9 mL
Stop Solution: 1 x 6 mL
Kit detection
Colorimetric
Kit duration
3h
Kit linearity
Sample - 1:2 Dilution - 1:4 Dilution - 1:8 Dilution - 1:16 Dilution
Serum (n=5) - 81-95% - 92-101% - 78-90% - 78-94%
EDTA Plasma (n=5) - 99-105% - 98-105% - 80-96% - 90-98%
Heparin Plasma (n=5) - 79-89% - 92-101% - 81-93% - 82-91%
Kit principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Egl Nine Homolog 1 (EGLN1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Egl Nine Homolog 1 (EGLN1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Egl Nine Homolog 1 (EGLN1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of Egl Nine Homolog 1 (EGLN1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Kit recovery
Matrix - Recovery Range (%) - Average (%)
Serum (n=5) - 91-101 - 96
EDTA Plasma (n=5) - 97-105 - 102
Heparin Plasma (n=5) - 84-101 - 91
Kit reproducibility
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Egl Nine Homolog 1 (EGLN1) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Egl Nine Homolog 1 (EGLN1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
Sample Type
Serum, plasma, tissue homogenates, cell lysates and other biological fluids

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 96 Wells
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen