Vergleich

ITGB2 ELISA Kit (Human)

ArtNr OKCD02660
Hersteller AVIVA Systems Biology
Menge 96 Wells
Kategorie
Typ Elisa-Kit
Applikationen ELISA
Specific against Human (Homo sapiens)
Sensitivity 0.122 ng/mL
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias CD18;cell surface adhesion glycoprotein (LFA-1/CR3/P150,959 beta subunit precursor);Cell surface adhesion glycoproteins LFA-1/CR3/p150,95 subunit beta;complement component 3 receptor 3 and 4 subunit;complement receptor C3 beta-subunit;Complement receptor C3 subunit beta;integrin beta chain,beta 2;integrin beta-2;integrin,beta 2 (complement component 3 receptor 3 and 4 subunit);LAD;LCAMB;leukocyte cell adhesion molecule CD18;leukocyte-associated antigens CD18/11A,CD18/11B,CD18/11C;LFA-1;MAC-1;MF17;MFI7;truncated integrin beta-2.
Versandbedingung Gekühlt
Lieferbar
Manufacturer - Type
ELISA Kit
Manufacturer - Applications
Enzyme-linked Immunosorbent assay-Sandwich
Manufacturer - Category
Root Catalog/Products/ELISA Kits, Root Catalog/Products/Kit
Shipping Temperature
Wet Ice
Gene symbol
ITGB2
Gene Fullname
integrin subunit beta 2
Protein size
769
Reconstitution and storage
2°C to 8°C|-20°C
Description of target
Integrin ITGAL/ITGB2 is a receptor for ICAM1, ICAM2, ICAM3 and ICAM4. Integrins ITGAM/ITGB2 and ITGAX/ITGB2 are receptors for the iC3b fragment of the third complement component and for fibrinogen. Integrin ITGAX/ITGB2 recognizes the sequence G-P-R in fibrinogen alpha-chain. Integrin ITGAM/ITGB2 recognizes P1 and P2 peptides of fibrinogen gamma chain. Integrin ITGAM/ITGB2 is also a receptor for factor X. Integrin ITGAD/ITGB2 is a receptor for ICAM3 and VCAM1. Contributes to natural killer cell cytotoxicity (PubMed:15356110). Involved in leukocyte adhesion and transmigration of leukocytes including T-cells and neutrophils (PubMed:11812992, PubMed:28807980). Triggers neutrophil transmigration during lung injury through PTK2B/PYK2-mediated activation (PubMed:18587400). Integrin ITGAL/ITGB2 in association with ICAM3, contributes to apoptotic neutrophil phagocytosis by macrophages (PubMed:23775590). In association with alpha subunit ITGAM/CD11b, required for CD177-PRTN3-mediated activation of TNF primed neutrophils (PubMed:21193407).
Nucleotide accession_num
NM_000211.4
Protein accession_num
NP_000202.3
Protein name
Integrin beta-2
Manufacturer - Specificity
This assay has high sensitivity and excellent specificity for detection of Integrin Beta 2 (ITGb2).No significant cross-reactivity or interference between Integrin Beta 2 (ITGb2) and analogues was observed.
Assay info
Assay Methodology: Quantitative Sandwich ELISA
Kit Components
Component: Amount
Anti-ITGB2 Microplate: 96 Wells (12 x 8 Well strips)
ITGB2 Lyophilized Standard: 2
100X Biotinylated ITGB2 Detector Antibody: 1 x 120 uL
100X Avidin-HRP Conjugate: 1 x 120 uL
Standard Diluent: 1 x 20 mL
Detector Antibody Diluent: 1 x 12 mL
Conjugate Diluent: 1 x 12 mL
30X Wash Buffer: 1 x 20 mL
Stop Solution: 1 x 6 mL
TMB Substrate: 1 x 9 mL
Kit detection
Colorimetric
Kit duration
3h
Kit linearity
Sample - 1:2 - 1:4 - 1:8 - 1:16
- 95-102% - 92-105% - 99-105% - 80-104%
Kit principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Integrin Beta 2 (CD18). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Integrin Beta 2 (CD18). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Integrin Beta 2 (CD18), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of Integrin Beta 2 (CD18) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Kit recovery
Matrix - Recovery range (%) - Average(%)
- 95-103 - 101
Kit reproducibility
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Integrin Beta 2 (CD18) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Integrin Beta 2 (CD18) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
Sample Type
Tissue homogenates, cell lysates, cell culture cell supernatant and other biological fluids

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 96 Wells
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen