Vergleich

SLIT2 ELISA Kit (Rat)

ArtNr OKCD02863
Hersteller AVIVA Systems Biology
Menge 96 Wells
Kategorie
Typ Elisa-Kit
Applikationen ELISA
Specific against Rat (Rattus norvegicus)
Sensitivity 30 pg/mL
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias Slit-2,Slit homolog 2 protein
Versandbedingung Gekühlt
Lieferbar
Manufacturer - Type
ELISA Kit
Manufacturer - Applications
Enzyme-linked Immunosorbent assay-Sandwich
Manufacturer - Category
Root Catalog/Products/ELISA Kits, Root Catalog/Products/Kit, Root Catalog/Research Areas/Neuroscience ELISA Kits
Shipping Temperature
Wet Ice
Gene symbol
SLIT2
Protein size
766
Reconstitution and storage
2°C to 8°C|-20°C
Description of target
Thought to act as molecular guidance cue in cellular migration, and function appears to be mediated by interaction with roundabout homolog receptors. During neural development involved in axonal navigation at the ventral midline of the neural tube and projection of axons to different regions. SLIT1 and SLIT2 seem to be essential for midline guidance in the forebrain by acting as repulsive signal preventing inappropriate midline crossing by axons projecting from the olfactory bulb. In spinal chord development may play a role in guiding commissural axons once they reached the floor plate by modulating the response to netrin. In vitro, silences the attractive effect of NTN1 but not its growth-stimulatory effect and silencing requires the formation of a ROBO1-DCC complex. May be implicated in spinal chord midline post-crossing axon repulsion. In vitro, only commissural axons that crossed the midline responded to SLIT2. In the developing visual system appears to function as repellent for retinal ganglion axons by providing a repulsion that directs these axons along their appropriate paths prior to, and after passage through, the optic chiasm. In vitro, collapses and repels retinal ganglion cell growth cones. Seems to play a role in branching and arborization of CNS sensory axons, and in neuronal cell migration. Seems to be involved in regulating leukocyte migration (By similarity).
Nucleotide accession_num
NM_022632.2
Protein accession_num
NP_072154.2
Protein name
Slit homolog 2 protein
Manufacturer - Specificity
This assay has high sensitivity and excellent specificity for detection of Slit Homolog 2 (Slit2).No significant cross-reactivity or interference between Slit Homolog 2 (Slit2) and analogues was observed.
Assay info
Assay Methodology: Quantitative Sandwich ELISA
Kit Components
Component: Amount
Anti-SLIT2 Microplate: 96 Wells (12 x 8 Well strips)
SLIT2 Lyophilized Standard: 2
100X Biotinylated SLIT2 Detector Antibody: 1 x 120 uL
100X Avidin-HRP Conjugate: 1 x 120 uL
Standard Diluent: 1 x 20 mL
Detector Antibody Diluent: 1 x 12 mL
Conjugate Diluent: 1 x 12 mL
30X Wash Buffer: 1 x 20 mL
Stop Solution: 1 x 6 mL
TMB Substrate: 1 x 9 mL
Kit detection
Colorimetric
Kit duration
3h
Kit linearity
Sample - 1:2 - 1:4 - 1:8 - 1:16
Serum (n=5) - 95-103% - 88-102% - 79-93% - 93-105%
EDTA Plasma (n=5) - 80-92% - 98-105% - 89-99% - 80-101%
Heparin Plasma (n=5) - 99-105% - 90-99% - 95-105% - 81-103%
Kit principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Slit Homolog 2 (Slit2). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Slit Homolog 2 (Slit2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Slit Homolog 2 (Slit2), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of Slit Homolog 2 (Slit2) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Kit recovery
Matrix - Recovery range (%) - Average(%)
Serum (n=5) - 79-96 - 91
EDTA Plasma (n=5) - 90-98 - 94
Heparin Plasma(n=5) - 98-105 - 101
Kit reproducibility
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Slit Homolog 2 (Slit2) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Slit Homolog 2 (Slit2) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
Sample Type
Serum, plasma, tissue homogenates and other biological fluids

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 96 Wells
Lieferbar: In stock
lieferbar

Lieferung vsl. bis 30.10.2025 

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen