Vergleich

STAT1 ELISA Kit (Human)

ArtNr OKCD02896
Hersteller AVIVA Systems Biology
Menge 96 Wells
Kategorie
Typ Elisa-Kit
Applikationen ELISA
Specific against Human (Homo sapiens), Mouse (Murine, Mus musculus), Rat (Rattus norvegicus)
Sensitivity 0.115 ng/mL
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias CANDF7;IMD31A;IMD31B;IMD31C;ISGF-3;signal transducer and activator of transcription 1,91kD;signal transducer and activator of transcription 1,91kDa;signal transducer and activator of transcription 1-alpha/beta;STAT91;transcription factor ISGF-3 components p91/p84.
Versandbedingung Gekühlt
Lieferbar
Manufacturer - Type
ELISA Kit
Manufacturer - Applications
Enzyme-linked Immunosorbent assay-Sandwich
Manufacturer - Category
Root Catalog/Products/ELISA Kits, Root Catalog/Products/Kit
Shipping Temperature
Wet Ice
Gene symbol
STAT1
Gene Fullname
signal transducer and activator of transcription 1
Protein size
750
Reconstitution and storage
2°C to 8°C|-20°C
Description of target
Signal transducer and transcription activator that mediates cellular responses to interferons (IFNs), cytokine KITLG/SCF and other cytokines and other growth factors. Following type I IFN (IFN-alpha and IFN-beta) binding to cell surface receptors, signaling via protein kinases leads to activation of Jak kinases (TYK2 and JAK1) and to tyrosine phosphorylation of STAT1 and STAT2. The phosphorylated STATs dimerize and associate with ISGF3G/IRF-9 to form a complex termed ISGF3 transcription factor, that enters the nucleus (PubMed:28753426). ISGF3 binds to the IFN stimulated response element (ISRE) to activate the transcription of IFN-stimulated genes (ISG), which drive the cell in an antiviral state. In response to type II IFN (IFN-gamma), STAT1 is tyrosine- and serine-phosphorylated (PubMed:26479788). It then forms a homodimer termed IFN-gamma-activated factor (GAF), migrates into the nucleus and binds to the IFN gamma activated sequence (GAS) to drive the expression of the target genes, inducing a cellular antiviral state. Becomes activated in response to KITLG/SCF and KIT signaling. May mediate cellular responses to activated FGFR1, FGFR2, FGFR3 and FGFR4.
Nucleotide accession_num
NM_007315.3
Protein accession_num
NP_009330.1
Protein name
Signal transducer and activator of transcription 1-alpha/beta
Manufacturer - Specificity
This assay has high sensitivity and excellent specificity for detection of Signal Transducer And Activator Of Transcription 1 (STAT1).No significant cross-reactivity or interference between Signal Transducer And Activator Of Transcription 1 (STAT1) and analogues was observed.
Assay info
Assay Methodology: Quantitative Sandwich ELISA
Kit Components
Component: Amount
Anti-STAT1 Microplate: 96 Wells (12 x 8 Well strips)
STAT1 Lyophilized Standard: 2
100X Biotinylated STAT1 Detector Antibody: 1 x 120 uL
100X Avidin-HRP Conjugate: 1 x 120 uL
Standard Diluent: 1 x 20 mL
Detector Antibody Diluent: 1 x 12 mL
Conjugate Diluent: 1 x 12 mL
30X Wash Buffer: 1 x 20 mL
Stop Solution: 1 x 6 mL
TMB Substrate: 1 x 9 mL
Kit detection
Colorimetric
Kit duration
3h
Kit principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Signal Transducer And Activator Of Transcription 1 (STAT1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Signal Transducer And Activator Of Transcription 1 (STAT1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Signal Transducer And Activator Of Transcription 1 (STAT1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of Signal Transducer And Activator Of Transcription 1 (STAT1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Kit reproducibility
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Signal Transducer And Activator Of Transcription 1 (STAT1) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Signal Transducer And Activator Of Transcription 1 (STAT1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
Sample Type
Tissue homogenates, cell lysates and other biological fluids

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 96 Wells
Lieferbar: In stock
lieferbar

Lieferung vsl. bis 13.11.2025 

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen