Vergleich

PAPPA2 Chemi-Luminescent ELISA Kit (Human)

ArtNr OKCD03854
Hersteller AVIVA Systems Biology
Menge 96 Wells
Kategorie
Typ Elisa-Kit
Applikationen CLIA, IA
Specific against Human (Homo sapiens)
Sensitivity 0.312 ng/mL
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias PAPP-A2;pappalysin-2;PAPPE;PAPP-E;PLAC3;placenta-specific 3;pregnancy-associated plasma preproprotein-A2;Pregnancy-associated plasma protein A2;pregnancy-associated plasma protein E1;SSDA.
Versandbedingung Gekühlt
Lieferbar
Manufacturer - Type
ELISA Kit
Manufacturer - Category
Root Catalog/Products/ELISA Kits, Root Catalog/Products/Kit
Shipping Temperature
Wet Ice
Gene symbol
PAPPA2
Gene Fullname
pappalysin 2
Reconstitution and storage
2°C to 8°C|-20°C
Description of target
Metalloproteinase which specifically cleaves insulin-like growth factor binding protein (IGFBP)-5 at the '163-Ser-|-Lys-164' bond. Shows limited proteolysis toward IGFBP-3.
Nucleotide accession_num
NM_020318
Protein accession_num
NP_064714
Protein name
Pappalysin-2
Assay info
Assay Methodology: Quantitative Sandwich ELISA
Kit Components
Component: Amount
PAPPA2 Microplate: 96 Wells (12 x 8 Well strips)
PAPPA2 Lyophilized Standard: 2
100X PAPPA2 Biotinylated Detector Anitbody: 1 x 120 uL
100X Avidin-HRP Conjugate: 1 x 120 uL
Standard Diluent: 1 x 20 mL
Detector Antibody Diluent: 1 x 12 mL
Conjugate Diluent: 1 x 12 mL
30X Wash Buffer: 1 x 20 mL
100X Luminol Substrate: 1 x 2 mL
Substrate Diluent: 1 x 20 mL
Kit detection
Chemiluminescent
Kit duration
2h, 40min
Kit linearity
Sample - 1:2 - 1:4 - 1:8 - 1:16
Serum (n=5) - 96-104% - 78-102% - 80-94% - 93-101%
EDTA Plasma (n=5) - 96-103% - 83-101% - 81-99% - 84-91%
Heparin Plasma (n=5) - 92-99% - 81-97% - 95-104% - 96-104%
Kit principle
The microplate provided in this kit has been pre-coated with an antibody specific to Pappalysin 2 (PAPPA2). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Pappalysin 2 (PAPPA2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Pappalysin 2 (PAPPA2) level in the sample or standard.
Kit recovery
Matrix - Recovery range (%) - Average(%)
Serum (n=5) - 81-102 - 98
EDTA Plasma (n=5) - 78-99 - 90
Heparin Plasma (n=5) - 89-96 - 92
Kit reproducibility
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Pappalysin 2 (PAPPA2) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Pappalysin 2 (PAPPA2) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
Sample Type
Serum, plasma and other biological fluids

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 96 Wells
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen