Vergleich

LTB Chemi-Luminescent ELISA Kit (Mouse)

ArtNr OKCD03961
Hersteller AVIVA Systems Biology
Menge 96 Wells
Kategorie
Typ Elisa-Kit
Applikationen CLIA, IA
Specific against Mouse (Murine, Mus musculus)
Sensitivity 15.6 pg/mL
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias AI662801;LTbe;LTbeta;LT-beta;lymphotoxin-beta;p3;p33;Tnf;Tnfc;TNF-C;Tnfs;Tnfsf3;Tnlg1c;tumor necrosis factor C;tumor necrosis factor ligand 1c;tumor necrosis factor ligand superfamily member 3.
Versandbedingung Gekühlt
Lieferbar
Manufacturer - Type
ELISA Kit
Manufacturer - Category
Root Catalog/Products/ELISA Kits, Root Catalog/Products/Kit
Shipping Temperature
Wet Ice
Gene symbol
Ltb
Gene Fullname
lymphotoxin B
Reconstitution and storage
2°C to 8°C|-20°C
Description of target
Cytokine that binds to LTBR/TNFRSF3. May play a specific role in immune response regulation. Provides the membrane anchor for the attachment of the heterotrimeric complex to the cell surface.
Nucleotide accession_num
NM_008518
Protein accession_num
NP_032544
Protein name
Lymphotoxin-beta
Assay info
Assay Methodology: Quantitative Sandwich ELISA
Kit Components
Component: Amount
Ltb Microplate: 96 Wells (12 x 8 Well strips)
Ltb Lyophilized Standard: 2
100X Ltb Biotinylated Detector Anitbody: 1 x 120 uL
100X Avidin-HRP Conjugate: 1 x 120 uL
Standard Diluent: 1 x 20 mL
Detector Antibody Diluent: 1 x 12 mL
Conjugate Diluent: 1 x 12 mL
30X Wash Buffer: 1 x 20 mL
100X Luminol Substrate: 1 x 2 mL
Substrate Diluent: 1 x 20 mL
Kit detection
Chemiluminescent
Kit duration
2h, 40min
Kit linearity
Sample - 1:2 - 1:4 - 1:8 - 1:16
Serum (n=5) - 94-101% - 78-95% - 82-104% - 93-102%
EDTA Plasma (n=5) - 78-95% - 80-102% - 89-97% - 94-103%
Heparin Plasma (n=5) - 97-105% - 96-104% - 94-102% - 78-101%
Kit principle
The microplate provided in this kit has been pre-coated with an antibody specific to Lymphotoxin Beta (LTb). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Lymphotoxin Beta (LTb). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Lymphotoxin Beta (LTb) level in the sample or standard.
Kit recovery
Matrix - Recovery range (%) - Average(%)
Serum (n=5) - 86-95 - 90
EDTA Plasma (n=5) - 91-101 - 95
Heparin Plasma (n=5) - 89-97 - 93
Kit reproducibility
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Lymphotoxin Beta (LTb) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Lymphotoxin Beta (LTb) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
Sample Type
Serum, plasma and other biological fluids

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 96 Wells
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen