Vergleich

IL-4 ELISA Kit (Guinea Pig )

ArtNr OKCD05846
Hersteller AVIVA Systems Biology
Menge 96 Wells
Kategorie
Typ Elisa-Kit
Applikationen ELISA
Specific against Guinea Pig
Sensitivity < 1.24pg/mL
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias Il-4;IL-4 delta 3;interleukin-4.
Versandbedingung Gekühlt
Lieferbar
Specificity Cavia porcellus, Guinea Pig
Manufacturer - Type
ELISA Kit
Manufacturer - Applications
Enzyme-linked Immunosorbent assay-Sandwich
Manufacturer - Category
Root Catalog/Products/ELISA Kits, Root Catalog/Products/Kit
Shipping Temperature
Wet Ice
Gene symbol
Il4
Gene Fullname
interleukin 4
Reconstitution and storage
2°C to 8°C|-20°C
Description of target
Interleukin-4
Nucleotide accession_num
NM_001257263.1
Protein accession_num
NP_001244192.1
Protein name
Interleukin-4
Kit Components
Component: Amount
IL-4 Microplate: 96 Wells (12 x 8 Well strips)IL-4 Lyophilized Standard: 2100X IL-4 HRP-Detector Anitbody: 1 x 120 uL100X Avidin-HRP Conjugate: 1 x 120 uLStandard Diluent: 1 x 20 mLDetector Antibody Diluent: 1 x 12 mLConjugate Diluent: 1 x 12 mL30X Wash Buffer: 1 x 20 mLTMB Substrate: 1 x 2 mLStop Solution: 1 x 20 mL
Kit detection
Colorimetric
Kit duration
3h
Kit principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Interleukin 4 (IL4). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Interleukin 4 (IL4). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Interleukin 4 (IL4), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of Interleukin 4 (IL4) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Kit reproducibility
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 4 (IL4) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 4 (IL4) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
Sample Type
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 96 Wells
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen