Vergleich

CXCR7 ELISA Kit (Human)

ArtNr OKCD07435
Hersteller AVIVA Systems Biology
Menge 96 Wells
Kategorie
Typ Elisa-Kit
Applikationen ELISA
Specific against Human (Homo sapiens)
Sensitivity < 0.056ng/mL
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias atypical chemokine receptor 3;chemokine (C-X-C motif) receptor 7;chemokine orphan receptor 1;CMKOR1;C-X-C chemokine receptor type 7;CXCR7;CXCR-7;CXC-R7;G protein-coupled receptor;GPR159;G-protein coupled receptor 159;G-protein coupled receptor RDC1 homolog;RDC1;RDC-1.
Versandbedingung Gekühlt
Lieferbar
Manufacturer - Type
ELISA Kit
Manufacturer - Applications
Enzyme-linked Immunosorbent assay-Sandwich
Manufacturer - Category
Root Catalog/Products/ELISA Kits, Root Catalog/Products/Kit
Shipping Temperature
Wet Ice
Gene symbol
ACKR3
Gene Fullname
atypical chemokine receptor 3
Reconstitution and storage
2°C to 8°C|-20°C
Description of target
Atypical chemokine receptor that controls chemokine levels and localization via high-affinity chemokine binding that is uncoupled from classic ligand-driven signal transduction cascades, resulting instead in chemokine sequestration, degradation, or transcytosis. Also known as interceptor (internalizing receptor) or chemokine-scavenging receptor or chemokine decoy receptor. Acts as a receptor for chemokines CXCL11 and CXCL12/SDF1. Chemokine binding does not activate G-protein-mediated signal transduction but instead induces beta-arrestin recruitment, leading to ligand internalization and activation of MAPK signaling pathway. Required for regulation of CXCR4 protein levels in migrating interneurons, thereby adapting their chemokine responsiveness. In glioma cells, transduces signals via MEK/ERK pathway, mediating resistance to apoptosis. Promotes cell growth and survival. Not involved in cell migration, adhesion or proliferation of normal hematopoietic progenitors but activated by CXCL11 in malignant hemapoietic cells, leading to phosphorylation of ERK1/2 (MAPK3/MAPK1) and enhanced cell adhesion and migration. Plays a regulatory role in CXCR4-mediated activation of cell surface integrins by CXCL12. Required for heart valve development. Acts as coreceptor with CXCR4 for a restricted number of HIV isolates.
Nucleotide accession_num
NM_020311.2
Protein accession_num
NP_064707.1
Protein name
Atypical chemokine receptor 3
Kit Components
Component: Amount
CXCR7 Microplate: 96 Wells (12 x 8 Well strips)CXCR7 Lyophilized Standard: 2100X CXCR7 HRP-Detector Anitbody: 1 x 120 uL100X Avidin-HRP Conjugate: 1 x 120 uLStandard Diluent: 1 x 20 mLDetector Antibody Diluent: 1 x 12 mLConjugate Diluent: 1 x 12 mL30X Wash Buffer: 1 x 20 mLTMB Substrate: 1 x 9 mLStop Solution: 1 x 6 mL
Kit detection
Colorimetric
Kit duration
3h
Kit principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Chemokine C-X-C-Motif Receptor 7 (CXCR7). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Chemokine C-X-C-Motif Receptor 7 (CXCR7). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Chemokine C-X-C-Motif Receptor 7 (CXCR7), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of Chemokine C-X-C-Motif Receptor 7 (CXCR7) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Kit reproducibility
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Chemokine C-X-C-Motif Receptor 7 (CXCR7) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Chemokine C-X-C-Motif Receptor 7 (CXCR7) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
Sample Type
Serum, plasma, tissue homogenates, cell lysates and other biological fluids

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 96 Wells
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 