Gold-in-a-Box Conjugation Kit, 40 nm, 44 mL

ArtNr NGIB40-B044
Hersteller Bioassay Works
Menge 44 mL
Kategorie
Typ Beads Based kits
Specific against other
ECLASS 10.1 32161000
ECLASS 11.0 32161000
UNSPSC 41116126
Lieferbar
Description
The Gold-in-a-Box Conjugation Kit, 40 nm, contains the reagents required to prepare highly-reactive antibody or soluble protein gold conjugates that can be utilized in lateral-flow assays.
The key to most high-performance lateral-flow assays is the ability to covalently attach antibodies/proteins to gold nanoparticles. The Gold-in-a-Box Conjugation Kit enables optimal binding of an antibody/protein to our Naked Gold 40 nm highly concentrated gold sol, while retaining a high degree of specific activity through adjusting the pH of the gold sols to slightly above the isoelectric point of the coating antibody/protein. This is done through a series of pH titrations with the provided buffers. The Gold-in-a-Box kit allows researchers and assay developers to quickly (in less than 50 minutes) determine the pI and optimal coating conditions for your antibody or soluble protein and to perform the conjugation reaction. A sample preparation and gold conjugation procedure is provided.
Reagents are also provided to coat the resultant gold conjugates on polyester of glass fiber ribbon.

Kit Contents:

NG40-B044 – Naked Gold 40 nm Concentrated Gold Sol at 15 O.D./mL, 44 mL
BUFA-001 – Buffer Solution A, 1.0 mL
BUFB-001 – Buffer Solution B, 1.0 mL
BUFC-001 – Buffer Solution C, 1.0 mL
BUFD-001 – Buffer Solution D, 1.0 mL
BLK-005 – BSA Blocking Stabilizer Solution, 5.0 mL
CDB-005 – Gold Drying Buffer, 5.0 mL
Weight
.35 lbs
Dimensions
4 x 6 x 2.5 in
Storage Temperature
Refrigerated (2-8C), do not freeze
Shipping Temperature
Ambient temperatures
Stability
2 years from date of manufacture
References
Victoria Martinez-Sernandez, Laura Muino, Maria Jesus Perteguer, Teresa Garate, Mercedes Mezo, Marta Gonzalez-Warleta, Antonio Muro, Jose Manuel Correia da Costa, Fernanda Romaris, Florencio M. Ubeira. Development and Evaluation of a New Lateral Flow Immunoassay for Serodiagnosis of Human Fasciolosis. 2011.

Giyoung Kim, Ji-Hea Moon, Saet Byeol Park, Youn-Jung Jang, Jongguk Lim, Changyeun Mo. Image Analysis of a Lateral Flow Strip Sensor for the Detection of Escherichia coli O157:H7. Journal of Biosystems Engineering. 2013; 38(4): 335-340.

Sangdae Lee, Giyoung Kim and Jihea Moon. Performance Improvement of the One-Dot Lateral Flow Immunoassay for Aflatoxin B1 by Using a Smartphone-Based Reading System. Sensors. 2013; 13(4): 5109-5116.

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 44 mL
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen