Vergleich

HaCaT Europäischer Partner

Hersteller CLS Cell Lines Service
Kategorie
Typ Cell line
Specific against Human
Menge 1 cryovial
ArtNr CLS-300493
eClass 6.1 32160890
eClass 9.0 32160890
Lieferbar
Manufacturers Category
HaCaT cells and derivatives
Tissue
Skin
Age
62 years
Gender
Male
Ethnicity
Caucasian
Cell Type
Keratinocyte
Growth Properties
Adherent
Biosafety Level
1
Tumorigenic
No
Karyotype
Aneuploid (hypotetraploid)
Culture Medium
DMEM
Medium Supplements
10% FBS, 2 mM L-glutamine, 4.5 g/L glucose
Passaging Solution
The 1:1 mixture of EDTA (stock. 0.05%) and trypsin (stock: 0.1%) must be prepared each time ahead of detaching the cells using PBS without Ca2+ and Mg2+ to provide a physiologic osmolarity. Ready-to-use mixtures of trypsin/EDTA are not recommended, as this may result in cell clumps. As an alternative, TrypLE Express (Life Technologies) instead of trypsin/EDTA can be used. The protocol of the manufacturer should be followed.
Subculturing
Remove the culture medium and rinse the adherent cells using PBS without calcium and magnesium (3-5 ml PBS for T25, 5-10ml for T75 cell culture flasks). Add freshly prepared 0.05% EDTA solution, 1-2ml per T25, 2.5ml per T75 cell culture flask, the cell sheet must be covered completely, and incubate at 37 ?C for 10 min. Add freshly prepared trypsin/EDTA, 0.05%/0.025% solution *2 (1ml per T25, 2.5ml per T75 cell culture flask), the cell sheet must be covered completely. The cells must detach within 1-2 minutes. Stop the trypsin activity using FBS-containing cell culture medium. Dispense into new flasks which contain fresh cell culture medium.
Split Ratio
A ratio of 1:5 to 1:10 is recommended
Seeding Density
1 x 10^4 cells/cm^2
Fluid Renewal
2 times per week
Freeze Medium
Amelogenin
X, X
NOTE
Deutsch:
Universitäre Kunden: Für den Erwerb ist ein Material Transfer Agreement oder eine Limited Use Label License auszufüllen.
Kommerzielle Kunden: Für den Erwerb ist ein Material Transfer Agreement oder ein Master Supply Agreement auszufüllen.
Nach eingegangener Bestellung werden ihnen alle relevanten Dokumente zugeschickt.

English:
University Customers: A Material Transfer Agreement or Limited Use Label License must be completed for purchase.
Commercial Customers: A Material Transfer Agreement or Master Supply Agreement must be completed for purchase.
After the order is received, all relevant documents will be sent to you.

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 1 cryovial
Lieferbar: In stock
lieferbar

Lieferung vsl. bis 23.05.2024 

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen