ArtNr |
CLS-605470 |
Hersteller |
CLS Cell Lines Service
|
Menge |
1 cryovial |
Kategorie |
|
Typ |
Cell line |
Zertifikat |
The certificate of analysis can be requested on the website or via email at info@cytion.com. Please indicate the lot number of your product in the email. |
Specific against |
Monkey (Cynomolgus, Simian), Primate |
Dry ice |
Yes
|
ECLASS 10.1 |
42040401 |
ECLASS 11.0 |
42040401 |
UNSPSC |
41106509 |
Alias |
Cos-7, COS7, Cos7, CV-1 in Origin Simian-7 |
Lieferbar |
|
Specificity |
Cercopithecus aethiops (Green monkey) |
Manufacturer - Applications |
Transfection host. Suitable for transfection by vectors requiring expression of SV40 T antigen. |
Manufacturer - Category |
Monkey cell lines |
Description |
COS-7 cells are a fibroblast-like cell line derived from African green monkey kidney tissue and are a vital resource in research, particularly for their high transfection efficiency, making them a popular choice for the expression of recombinant proteins. COS-7 cells are derived from the CV-1 cell line and transformed with a mutant form of the simian virus 40 (SV40), which includes a replication origin that allows for episomal replication of transfected plasmids containing the SV40 origin of replication. Transfection of COS-7 cells is facilitated by transfection reagents such as Lipofectamine, with an efficiency that mirrors those observed in HeLa cells. Conventional methods can achieve up to 80% transfection efficiency in COS-7 cells, showcasing their ease of genetic manipulation. The ability of COS-7 cells to accommodate large plasmids and replicate them, leading to high yields of the desired recombinant proteins, make them an invaluable resource for various applications, including gene expression studies, signal transduction pathway investigations, and the production of proteins for biochemical analyses. COS-7 cells exhibit a strong susceptibility to various viruses, making them an excellent model for virology studies, including virus-host interaction investigations, viral life cycle elucidation, and antiviral drug testing. Their permissiveness to viral entry and replication is leveraged to study the mechanisms of viral infection, pathogenesis, and the cellular responses elicited by viral invaders. Consequently, COS-7 cells serve as a valuable tool in the development of viral vectors for gene therapy and vaccine research. COS-7 cells are a cornerstone in research due to their high transfection efficiency and utility in recombinant protein expression. Their ease of genetic manipulation, combined with susceptibility to viruses, makes them indispensable for studies in gene expression, signal transduction, virology, and the development of viral vectors, solidifying their role as a versatile tool in both basic and applied biological sciences. |
Tissue |
Kidney |
Growth properties |
Monolayer, adherent |
Cell type |
Fibroblast |
Age |
Adult |
Gender |
Male |
Morphology |
Fibroblast-like |
Biosafety Level |
1 |
Culture Medium |
DMEM:Ham's F12, w: 3.1 g/L Glucose, w: 1.6 mM L-Glutamine, w: 15 mM HEPES, w: 1.0 mM Sodium pyruvate, w: 1.2 g/L NaHCO3 (Cytion article number 820400a) |
Medium Supplements |
Supplement the medium with 10% FBS |
Subculturing |
Remove the old medium from the adherent cells and wash them with PBS that lacks calcium and magnesium. For T25 flasks, use 3-5 ml of PBS, and for T75 flasks, use 5-10 ml. Then, cover the cells completely with Accutase, using 1-2 ml for T25 flasks and 2.5 ml for T75 flasks. Let the cells incubate at room temperature for 8-10 minutes to detach them. After incubation, gently mix the cells with 10 ml of medium to resuspend them, then centrifuge at 300xg for 3 minutes. Discard the supernatant, resuspend the cells in fresh medium, and transfer them into new flasks that already contain fresh medium. |
Fluid Renewal |
2 to 3 times per week |
Freezing Recovery |
After thawing, plate the cells at 5 x 10^4 cells/cm^2 and allow the cells to recover from the freezing process and to adhere for at least 24 hours. |
Freeze Medium |
|
Handling of Cryopreserved Cultures |
Confirm that the vial remains deeply frozen upon delivery, as cells are shipped on dry ice to maintain optimal temperatures during transit.
Upon receipt, either store the cryovial immediately at temperatures below -150° C to ensure the preservation of cellular integrity, or proceed to step 3 if immediate culturing is required.
For immediate culturing, swiftly thaw the vial by immersing it in a 37° C water bath with clean water and an antimicrobial agent, agitating gently for 40-60 seconds until a small ice clump remains.
Perform all subsequent steps under sterile conditions in a flow hood, disinfecting the cryovial with 70% ethanol before opening.
Carefully open the disinfected vial and transfer the cell suspension into a 15 ml centrifuge tube containing 8 ml of room-temperature culture medium, mixing gently.
Centrifuge the mixture at 300 x g for 3 minutes to separate the cells and carefully discard the supernatant containing residual freezing medium.
Gently resuspend the cell pellet in 10 ml of fresh culture medium. For adherent cells, divide the suspension between two T25 culture flasks; for suspension cultures, transfer all the medium into one T25 flask to promote effective cell interaction and growth.
Adhere to established subculture protocols for continued growth and maintenance of the cell line, ensuring reliable experimental outcomes.
|
Sterility |
Mycoplasma contamination is excluded using both PCR-based assays and luminescence-based mycoplasma detection methods. To ensure there is no bacterial, fungal, or yeast contamination, cell cultures are subjected to daily visual inspections. |
Required Documentation |
A CITES (Convention on International Trade in Endangered Species of Wild Fauna and Flora) certificate is required to export this article to your country. CITES oversees trade in specific species globally to ensure their protection and sustainability. Our company, as the exporter, will handle the CITES certificate application on your behalf. The process typically takes 2-4 weeks and incurs a fee of 70€. |
Safety Precautions |
When planning to store a cryovial in liquid nitrogen for future thawing, it is mandatory to adhere to stringent safety measures. Appropriate protective gloves and clothing are essential, and the use of a face mask or safety goggles is required during the transfer of frozen samples to or from the liquid nitrogen tank. This is to mitigate the risk of injury from potential cryovial explosions upon removal, which can result in the projection of sharp fragments. |
Disclaimer |
Our cells are provided for in vitro laboratory research purposes exclusively and are not intended for clinical or diagnostic use, nor are they to be administered to humans or used for veterinary purposes. Users must adhere to all applicable guidelines and regulations for the handling and use of these cells in a research setting. |
Warranty |
We stand by the promise of delivering products with high cell viability and robust culture performance. To achieve the best results, please make sure you follow the storage and culture instructions detailed in the product information sheet closely. Your adherence to these guidelines is key to success. |
Split Ratio |
A ratio of 1:4 to 1:8 is recommended |
Seeding Density |
1 x 10^4 cells/cm^2 will yield in a confluent layer in about 4 days |
Virus Susceptibility |
SV40 (lytic growth), SV40 tsA209 at 40?C, SV40 mutants with deletions in the early region |
Products |
T antigen |
NOTE |
Deutsch:Universitäre Kunden: Für den Erwerb ist ein Material Transfer Agreement oder eine Limited Use Label License auszufüllen. Kommerzielle Kunden: Für den Erwerb ist ein Material Transfer Agreement oder ein Master Supply Agreement auszufüllen.Nach eingegangener Bestellung werden ihnen alle relevanten Dokumente zugeschickt.English:University Customers: A Material Transfer Agreement or Limited Use Label License must be completed for purchase.Commercial Customers: A Material Transfer Agreement or Master Supply Agreement must be completed for purchase.After the order is received, all relevant documents will be sent to you. |
Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.
Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.