Vergleich

Human Interleukin 2 Receptor, Alpha, IL2RA ELISA Kit

ArtNr DEIA230
Hersteller Creative Diagnostics
Menge 96 T
Kategorie
Typ Elisa-Kit
Specific against other
Host Human
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias IL2RA,interleukin 2 receptor,alpha,CD25,IL2R,TCGFR,IDDM10,interleukin 2 receptor,alpha chain,Interleukin-2 receptor,IL-2-RA,IL2-RA,OTTHUMP00000019030,OTTHUMP00000044870,p55,CD25 antigen,IL-2 receptor alpha subunit,TAC antigen
Lieferbar
Storage Conditions
Unopened Kit: Store at 2 - 8oC. Donot use past kit expiration date. Opened/Reconstituted Reagents: Standardor Sample Diluent, Biotin-antibody Diluent, HRP-avidin Diluent, TMBSubstrate, Wash Buffer, TMB StopSolution.The above mentioned reagents should be stored for up to 1 month at 2 - 8oC. Microplate Wells: Return unused wellsto the foil pouch containing the desiccant pack, reseal along entire edge ofzip-seal. May be stored for up to 1 month at 2 - 8oC.
Intended Use
RUO, Thisassay is a sandwich Enzyme Linked-Immuno-Sorbent Assay (ELISA). It isdeveloped for quantitative measurement of Human IL2RA in serum, plasma and other biological fluids.
Sample
serum, plasma and other biological fluids
Full name
Interleukin 2 Receptor, Alpha
Abbr
Human IL2RA ELISA Kit
Gene Information - Gene Name
IL2RA interleukin 2receptor, alpha [ Homo sapiens ]
Gene Information - mRNA Refseq
NM_000417
Gene Information - Protein Refseq
NP_000408
Gene Information - MIM
147730
Gene Information - Pathway
Cytokine-cytokine receptorinteraction, Endocytosis, Hematopoietic cell lineage, Jak-STAT signalingpathway
Gene Information - Function
interleukin-2receptor activity, receptor activity
Gene Information - Offical Symbol
IL2RA
Principle Of The Test
Anantibody specific for Human IL2RA is coated onto the wells of the microtiterplate. Samples and standards of Human IL2RA are pipetted into the wells forbinding to the coated antibody. After washing procedure to remove unboundcompounds, an enzyme-linked antibody specific for Human IL2RA is added to thewells. Following a wash to remove any unbound antibody-enzyme reagent, asubstrate solution is added to the wells and color develops in proportion tothe amount of Human IL2RA bound in the initial step. The color development isstopped and the intensity of the color is measured. The magnitude of theabsorbance for this developed color is proportional to the amount of Human IL2RA.
Reagents And Materials Provided
Human IL2RAMicroplate: polystyrene microplate coated with a monoclonalantibody against Human IL2RA, Standard(freeze dried): 4, 000 pg/ml, 2vials, Biotin-antibody(100×): 2vials, HRP-avidin(100×):2vials, ReagentDiluent:25ml, 2vials, TMB Substrate:12ml, 1vial, TMB StopSolution: 1vial, WashBuffer (20×): 30 ml, 1 vial, Microtiterplate sealers: 3 sheets.
Materials Required But Not Supplied
1.Validated microplate reader. 2.Eppendorf Tubes for dilution for samples and standards. 3.Deionized or distilled water. 4.Validated adjustable micropipettes, single and multi-channel. 5.Automatic microtiter plate washer or manual vacuum aspiration equipment. 6. 37oCincubator.
Precautions
1.The kit should be equilibrated to room temperature (20-23oC) before openingany vials and starting the assay. It is highly recommended that the solutionsbe used as soon as possible after rehydration. 2.When mixing or reconstituting protein solutions, always avoid foaming. 3.Do not mix or substitute reagents with those from other lots or sources. 4.To avoid cross-contamination, change pipette tips between additions of eachstandard level, between sample additions, and between reagent additions.Also, use separate reservoirs for each reagent. 5.Crystals could appear in the 20X wash solution due to high salt concentrationin the stock solutions. Crystals are readily dissolved at room temperature orat 37C before dilution of the buffer solutions. 6.Keep TMB Substrate protected from light. 7.The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
ELISA Procedure
1. Prepare all reagents, working standards, and samples as directed in the previous sections. Diluteoriginal density Standard as follow: Set up 7 points of diluted standard suchas 4, 000 pg/mL, 2, 000 pg/mL, 1, 000 pg/mL, 500 pg/mL, 250 pg/Ml, 125 pg/mL, and62.5 pg/mL. The last EP tubes with Sample Diluent is the blank as 0 pg/mL. 2. Add 100ul ofStandard, Control or Sample per well. Cover with the Microtiter platesealers. Incubate for 1.5 hours at 37oC. 3. Aspirate eachwell and wash, Wash by filling each well with 1 x Wash Buffer using a squirtbottle, multi-channel pipette, manifold dispenser or autowasher. Completeremoval of liquid at each step is essential to good performance. Repeatingthe process twice for a total of four washes. After the last wash, removeany remaining 1× Wash Buffer by aspirating or decanting. Invert the plate andblot it against clean paper towels. 4. Add 100ul ofBiotin-antibody working solution to each well. Cover with the Microtiterplate sealers. Incubate for 1 hour at 37oC. Biotin-antibody working solutionmay appear cloudy. Warm to room temperature and mix gently until solutionappears uniform. 5. Repeat theAspirate/Wash four times. 6. Add 100ul ofHRP-avidin working solution to each well. Cover the microtiter plate with anew adhesive strip. Incubate for 0.5 hours at 37oC. 7. Repeat theAspirate/Wash four times. 8. Add 100ul TMBSubstrate to each well. Mix gently, protected from light and incubatesat 37C for 10-20 min. 9. Add one drop (100ul) of TMB Stop Solution to each well to stop the color reaction. If colorchange does not appear uniform, gently tap the plate to ensure thoroughmixing. 10. Determine theoptical density of each well within 5 minutes, using a microplate reader setto 450 nm.
Detection Method
Sandwich ELISA
Calculation Of Results
Average the duplicate readings for each standard, control, and samples and subtractthe average zero standard optical density. Plot the optical density for thestandards versus the concentration of the standards and draw the best curve.The data can be linearized by using log/log paper and regression analysis maybe applied to the log transformation. To determine the sample concentrationof each sample, first find the absorbance value on the y-axis and extend ahorizontal line to the standard curve. At the point of intersection, extend avertical line to the x-axis and read the corresponding sample concentration.If samples have been diluted, the concentration read from the standard curvemust be multiplied by the dilution factor.

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 96 T
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen