Hersteller United States Biological
CAS-Nr. 9068-38-6
Menge 50 KU
Kategorie
Typ Enzymes
Format Liquid
Specific against other
Purity ≥90%, Verified by SDS-PAGE
Dry ice Yes
ECLASS 10.1 32160410
ECLASS 11.0 32160410
UNSPSC 12352204
Versandbedingung Trockeneis
Lieferbar
Manufacturer - Category
Molecular Biology / MB-Enzymes
Shipping Temperature
Dry Ice
Storage Conditions
-20°C
Molecular Weight
71
Grade
Molecular Biology Grade
Form
Supplied as a liquid in 20mM Tris HCl, pH 7.5, 200mM sodium chloride, 0.1mM EDTA, 1mM DTT, 0.01% NP-40 and 50% glycerol.
EU Commodity Code
30021019
Description
Moloney Murine Leukemia Virus Reverse Transcriptase (M-MLV RT) is an RNA-dependent DNA polymerase that can be used in cDNA synthesis with long messenger RNA templates (> 5kb). M-MLV RT is the preferred reverse transcriptase for long mRNA templates because the RNase H activity of M-MLV RT is weaker than the commonly used Avian Myeloblastosis Virus (AMV) reverse transcriptase.

Unit Definition:
One unit is defined as that amount of enzyme required to catalyze the transfer of 1nmol of deoxynucleotide into acid-precipitable material in 10 minutes at 37°C. The reaction conditions are: 50mM Tris-HCl (pH 8.3), 7mM MgCl2, 40mM KCl, 10mM DTT, 0.1mg/ml BSA, 0.5mM [3H] dTTP, 0.025mM oligo(dT50), 0.25mM poly(A)400 and 0.01% NP-40.

Applications:
Suitable for use in In Situ Transcription, cDNA Library Synthesis and Screening, mRNA Structure Determination and Ribosomal Pause Site Determination.

Recommended Dilutions:
M-MLV Reverse Transcriptase is less processive than AMV Reverse Transcriptase, and therefore, more units of the M-MLV enzyme are required to generate the same amount of cDNA as in the AMV reaction. Thus, starting with 1µg of mRNA in a first-strand cDNA synthesis, 200 units of the M-MLV enzyme are recommended as opposed to 25 units of the AMV enzyme.
Optimal dilutions to be determined by researcher.

R1991A: 5X Reaction Buffer for Reverse Transcriptase, M-MLV (M-MLV-RT) 1x1ml (included):
5X: Supplied as a liquid in 250mM Tris-Hcl, pH 8.3 at RT, 375mM potassium chloride, 15mM magnesium chloride, 50mM DTT. Dilute 1:5 prior to use.
1X: 50mM Tris-HCl, pH 8.3 at RT, 75mM potassium chloride, 3mM magnesium chloride, 10mM DTT.

Quality Control Assays
Activity Assay: First-Strand cDNA Synthesis: First-strand cDNAs, of 1.2kb and 7.5kb control RNAs, are
synthesized at 37°C for 1 hour using 200u of M-MLV Reverse Transcriptase, 1ug of each template, an oligo(dT)15 primer and radiolabeled dCTP. The minimum specification is the production of 120ng of first-strand cDNA. The cDNA product must be >90% full-length for the 1.2kb control RNA as observed by gel electrophoresis and autoradiography. For the 7.5kb control RNA, 25% of the cDNA must migrate at 7.5kb.
Contaminant Activity: DNase and RNase Assay: To test for nuclease activity, 50ng of radiolabeled DNA or radiolabeled RNA is incubated with 200u of M-MLV Reverse Transcriptase in 1X Reaction Buffer for one hour at 37°C, and the release of radiolabeled nucleotides is monitored by scintillation counting of TCA-soluble material. Minimum passing specification is <1% release for both DNase and RNase.
Endonuclease Assay: To test for endonuclease activity, 1ug of Type I supercoiled plasmid DNA is incubated with 500u of M-MLV Reverse Transcriptase in 1X Reaction Buffer for one hour at 37°C. Following incubation, the supercoiled DNA is visualized on an ethidium bromide-stained agarose gel to verify the absence of visible nicking or cutting (analysis on 0.4ug of DNA).

Storage and Stability:
May be stored at 4°C for short-term only. For long-term storage, store at -20°C. Aliquots are stable for at least 6 months at -20°C. For maximum recovery of product, centrifuge the original vial after thawing and prior to removing the cap. Further dilutions can be made in assay buffer.
Shelf Life
6 months

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 50 KU
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen