Vergleich

CD51 (Integrin alphaV, Vitronectin alpha Subunit Receptor, VNR) (FITC)

ArtNr USB-C2405-11K
Hersteller United States Biological
Menge 100 tests
Kategorie
Typ Antibody Monoclonal
Format Liquid
Applikationen FC, IP, IHC, IC
Clon 13C2
Specific against Human (Homo sapiens)
Host Mouse
Isotype IgG1
Konjugat/Tag FITC
Purity Purified
ECLASS 10.1 42030590
ECLASS 11.0 42030590
UNSPSC 12352203
Versandbedingung Gekühlt
Lieferbar
Manufacturer - Type
Mab
Manufacturer - Category
Antibodies / Antibodies-CD Markers
Shipping Temperature
Blue Ice
Storage Conditions
-20°C
Grade
Purified
Form
Supplied as a liquid in PBS, 0.09% sodium azide. Labeled with Fluorescein isothiocyanate (FITC).
EU Commodity Code
30021010
Specificity
Recognizes human CD51.
Description
CD51 represents the 150kD integrin alphaV chain that associates with integrin beta3 (CD61) to form the CD51/CD61 vitronectin receptor on endothelial cells, certain activated leukocytes, NK cells, macrophages, neutrophils and platelets. CD51 is the most promiscuous integrin a subunit; it can form heterodimers with the beta1 (CD29), beta3 (CD61), beta5, beta6 and beta8 subunits in various tissues. CD51/CD61 acts as an activation-independent receptor for platelet attachment and spreading on vitronectin and other RGD-containing proteins, including matrix components. It also mediates leukocyte-endothelial cell adhesion via interaction with CD31.1-4

Applications:
Suitable for use in FLISA, Immunohistochemistry, Immunoprecipitation, Flow Cytometry and Immunocytochemistry. Other applications not tested.

Recommended Dilution:
Immunohistochemistry: frozen
Optimal dilutions to be determined by the researcher.

Storage and Stability:
Store product at 4°C if to be used immediately within two weeks. For long-term storage, aliquot to avoid repeated freezing and thawing and store at -20°C. Aliquots are stable at -20°C for 12 months after receipt. Dilute required amount only prior to immediate use. Further dilutions can be made in assay buffer.
Caution: FITC conjugates are sensitive to light. For maximum recovery of product, centrifuge the original vial after thawing and prior to removing the cap.

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 100 tests
Lieferbar: In stock