Vergleich

genesig Real-Time PCR Detection Kit for Human Herpes Virus 5 (HHV5 Glycoprotein B Gene), Standard

ArtNr USB-348917
Hersteller United States Biological
Menge 1Kit
Kategorie
Typ Detection Kits
Specific against other
ECLASS 10.1 32161090
ECLASS 11.0 32161090
UNSPSC 41116126
Versandbedingung Raumtemperatur
Lieferbar
Manufacturer - Category
Kits and Assays / Kits-PCR, genesig™
Shipping Temperature
RT
Storage Conditions
-20°C
EU Commodity Code
38220000
Description
The genesig® Kit for Human Herpes Virus 5 (Cytomegalovirus) genomes is designed for the in vitro quantification of CMV genomes. The kit is designed to have the broadest detection profile possible whilst remaining specific to the CMV genome. The primers and probe sequences in this kit have 100% homology with a broad range of CMV sequences based on a comprehensive bioinformatics analysis.

The target sequence (glycoprotein B) has previously been shown to be a good genetic marker for HHV5 in other real time PCR based studies (Guiver M et.al 2001). The primers and probe sequences in this kit have 100% homology with a broad range of clinically relevant reference
sequences based on a comprehensive bioinformatics analysis.

genesig Standard Kit:
Product features:
• Exceptional value for money
• Rapid detection of all clinically relevant subtypes
• Positive copy no. standard curve for quantification
• Highly specific detection profile
• High priming efficiency
• Broad dynamic detection range (>6 logs)
• Sensitive to < 100 copies of target
• Accurate controls to confirm findings

STANDARD KIT COMPONENTS:
• CMV specific primer/probe mix (150 reactions BROWN); FAM labelled
• CMV positive control template (RED); for standard curve
• RNAse/DNAse free water (WHITE); for resuspension of primer/probe mixes
• Template preparation buffer (YELLOW); for resuspension of positive control template and standard curve preparation

KIT STORAGE AND STABILITY:
This kit is stable at room temperature but should be stored at --20°C on arrival. Once the lyophilised components have been resuspended they should not be exposed to temperatures above -20°C for longer than 30 minutes at a time and unnecessary repeated freeze/thawing should be avoided. The kit is stable for six months from the date of resuspension under these circumstances.
If a standard curve dilution series is prepared this can be stored frozen for an extended period. If you see any degradation in this serial dilution a fresh standard curve can be prepared from the positive control.
We do not recommend using the kit after the expiry date stated on the pack.

REAGENTS AND EQUIPMENT TO BE SUPPLIER BY THE USER:
• Real-time PCR Instrument
• DNA extraction kit. This kit is recommended for use with genesig Easy DNA/RNA Extraction kit. However, it is designed to work well with all processes that yield high quality DNA with minimal PCR inhibitors.
• oasigTM lyophilized or PrecisionPLUS 2X qPCR Master Mix. This kit is intended for use with oasig or PrecisionPLUS2X qPCR Master Mix.
• Pipettors and tips
• Vortex and centrifuge
• Thin walled 1.5ml PCR reaction tubes

SUITABLE SAMPLE MATERIAL:
All kinds of sample material suited for PCR amplification can be used. Please ensure the samples are suitable in terms of purity, concentration, and DNA integrity. Always run at least one negative control with the samples. To prepare a negative-control, replace the template DNA sample with RNase/DNase free water.

DYNAMIC RANGE OF TEST:
Under optimal PCR conditions genesig CMV detection kits have very high priming efficiencies of >95% and can detect less than 100 copies of target template.

INSTRUMENTATION REQUIREMENTS:
Designed for use with real-time PCR instruments. For use in genesig® q16, look for the “Easy” nomenclature.


PRODUCT MANUAL:
http://www.genesig.com/assets/files/cmv_std.pdf

ABOUT THE genesig® KITS:
genesig® kits are sold for research use only and are not licensed for diagnostic procedures.

Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative Real-Time PCR kits for the detection and simultaneous quantification of numerous significant pathogens. A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.

The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented Real-Time PCR expertise in design and validation ensure the best possible kit. 

Details of the target and priming specificity are included in the individual handbooks above. Packaged, optimized and ready to use.

DNA/RNA EXTRACTION:
genesig® Easy DNA/RNA extraction kits are a simple to use, low cost and powerful extraction technology suitable for virtually all sample types.

Shelf Life
6 months

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 1Kit
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen