Vergleich

Human Soluble Vascular endothelial cell growth factor receptor 1 (sVEGFR-1) ELISA Kit

ArtNr ABK-KTE60057-48T
Hersteller Abbkine Scientific
Menge 48 T
Quantity options 48 T 96 T 96 T x 5 96 T x 50
Kategorie
Typ Elisa-Kit
Applikationen ELISA
Specific against Human (Homo sapiens)
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias VEGFR-1,Flt1,Fms-Related Tyrosine Kinase 1,Vascular Permeability Factor Receptor
Versandbedingung Gekühlt
Lieferbar
Manufacturer - Type
ELISA
Manufacturer - Applications
This Human Soluble Vascular endothelial cell growth factor receptor 1 (VEGFR-1) ELISA Kit employs a two-site sandwich ELISA to quantitate VEGFR-1 in samples. An antibody specific for VEGFR-1 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and anyVEGFR-1 present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for VEGFR-1 is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of VEGFR-1 bound in the initial step. The color development is stopped and the intensity of the color is measured.
Manufacturer - Category
Protein
Manufacturer - Conjugate / Tag
sVEGFR-1
Shipping Temperature
Gel pack with blue ice.
Storage Conditions
The unopened kit should be stored at 2 - 8°C. After opening, please store refer to protocols.
Background
FLT4, is a tyrosine kinase receptor for vascular endothelial growth factors C and D. The protein is thought to be involved in lymphangiogenesis and maintenance of the lymphatic endothelium. Mutations in this gene cause hereditary lymphedema type IA.The FLT4 mRNA signals first became detectable in the angioblasts of head mesenchyme, the cardinal vein, and extraembryonally in the allantois of 8.5-day p.c. postcoitus embryos. In 12.5-day p.c. embryos, the FLT4 signal decorated developing venous and presumptive lymphatic endothelia, but arterial endothelia were negative. FLT4 mRNA became restricted to vascular plexuses devoid of red cells, representing developing lymphatic vessels. In adult human tissues, only the lymphatic endothelia and some high endothelial venules expressed FLT4 mRNA.
Description
Human Soluble Vascular endothelial cell growth factor receptor 1 (sVEGFR-1) ELISA Kit employs a two-site sandwich ELISA to quantitate sVEGFR-1 in samples.
Precautions
The product listed herein is for research use only and is not intended for use in human or clinical diagnosis. Suggested applications of our products are not recommendations to use our products in violation of any patent or as a license. We cannot be responsible for patent infringements or other violations that may occur with the use of this product.
Features & Benefits
Human Soluble Vascular endothelial cell growth factor receptor 1 (VEGFR-1) ELISA Kit has high sensitivity and excellent specificity for detection of Human VEGFR-1. No significant cross-reactivity or interference between Human VEGFR-1 and analogues was observed.
Usage Notes
• Do not mix components from different kit lots or use reagents beyond the kit expiration date.
• Allow all reagents to warm to room temperature for at least 30 minutes before opening.
• Pre-rinse the pipet tip with reagent, use fresh pipet tips for each sample, standard and reagent to avoid contamination.
• Unused wells must be kept desiccated at 4 °C in the sealed bag provided.
• Mix Thoroughly is very important for the result. It is recommended using low frequency oscillator or slight hand shaking every 10 minutes.
• It is recommended that all samples and standards be assayed in duplicate or triplicate.
Kit components

Human Soluble Vascular endothelial cell growth factor receptor 1 microplate
Human Soluble Vascular endothelial cell growth factor receptor 1 standard
Human Soluble Vascular endothelial cell growth factor receptor 1 detect antibody
Streptavidin-HRP
Standard diluent
Assay buffer
HRP substrate
Stop solution
Wash buffer
Plate covers
Limit of detection
15 ng/L
Assay duration
Multiple steps standard sandwich ELISA assay with a working time of 3-5 hours. It depends on the experience of the operation person.
Assay type
Sandwich ELISA
Calibration range
187.5 ng/L-3000 ng/L
Detection method
Colorimetric
Sample type
Cell culture supernatants, Serum, Plasma, Other biological fluids
Product Assortment
ELISA Testing

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 48 T
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen