Vergleich

Mouse Cytokine Array C12

Hersteller Raybiotech
Kategorie
Typ Array
Specific against other
Menge 4 Sample Kit
ArtNr AAM-CYT-12-4
eClass 6.1 32161000
eClass 9.0 32161000
Lieferbar
Number of Targets Detected
40
Species Detected
Mouse
Compatible Sample Types
Cell Culture Supernatants
Cell Lysates
Plasma
Serum
Tissue Lysates
Design Principle
Sandwich-based
Method of Detection
Chemiluminescence
Quantitative/Semi-Quantitative
Semi-Quantitative
Solid Support
Membrane
Gene Symbols
Clmp | Cstb | Dll1 | Klk7 | Kremen2 | Lamp1 | Lrpap1 | Lrrc32 | Matn2 | Mep1a| MEPE | Mesd | Metrnl | Nectin2 | Ngfr | Nrtn | Ogn | Olfm1 | Omd | Osm | Osmr | Pcdh12 | Pdcd1 | Pdcd1lg2 | Pdgfrb | Pdpn | Pilrb | Pla2g2a | Plxna1 | Plxnc1 | Podxl | Prss34 | Reg2 | Rln1 | Rtn4r | Scarb2 | Tnfrsf11a | Tnfrsf4 | Tnfsf14 | Tpsb2
Application Information
Multiplexed Protein Detection
Detection of Relative Protein Expression
Detecting Patterns of Cytokine Expression
Biomarker/ Key Factor Screening
Identifying Key Factors
Confirming a Biological Process
Kit Components
Mouse Cytokine Antibody Array C12 Membranes
Blocking Buffer
Wash Buffer 1
Wash Buffer 2
Biotinylated Detection Antibody Cocktail
Streptavidin-
Conjugated H
R
P
Detection Buffer C
Detection Buffer D
Lysis Buffer8-
Well Incubation Tray
Plastic Sheets
Array Templates
Manual
Other Materials Required
Pipettors, pipet tips and other common lab consumables
Orbital shaker or oscillating rocker
Tissue Paper, blotting paper or chromatography paper
Adhesive tape or Saran Wrap
Distilled or de-ionized water
A chemiluminescent blot documentation system (such as U
V
P's Chemi
Doc-
It® or Epi
Chem I
I Benchtop Darkroom or G
E's Image
Quant™ L
A
S 4000 or Amersham Imagers 600 and 680), X-ray Film and a suitable film processor, or another chemiluminescent detection system.
Protocol Outline
Block membranes
Incubate with Sample
Incubate with Biotinylated Detection Antibody Cocktail
Incubate with H
R
P-
Conjugated Streptavidin
Incubate with Detection Buffers
Image with chemiluminescent imaging system
Perform densitometry and analysis

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

 
Schließen