Vergleich

VHL ELISA Kit (Rat)

ArtNr OKCD02977
Hersteller AVIVA Systems Biology
Menge 96 Wells
Kategorie
Typ Elisa-Kit
Applikationen ELISA
Specific against Rat (Rattus norvegicus)
Sensitivity 0.113 ng/mL
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias pVHL;Vhlh;von Hippel-Lindau disease tumor suppressor;von Hippel-Lindau protein;von Hippel-Lindau syndrome homolog;von Hippel-Lindau tumor suppressor,E3 ubiquitin protein ligase.
Versandbedingung Gekühlt
Lieferbar
Manufacturer - Type
ELISA Kit
Manufacturer - Applications
Enzyme-linked Immunosorbent assay-Sandwich
Manufacturer - Category
Root Catalog/Products/ELISA Kits, Root Catalog/Products/Kit
Shipping Temperature
Wet Ice
Gene symbol
Vhl
Gene Fullname
von Hippel-Lindau tumor suppressor
Protein size
185
Reconstitution and storage
2°C to 8°C|-20°C
Description of target
Involved in the ubiquitination and subsequent proteasomal degradation via the von Hippel-Lindau ubiquitination complex. Seems to act as a target recruitment subunit in the E3 ubiquitin ligase complex and recruits hydroxylated hypoxia-inducible factor (HIF) under normoxic conditions. Involved in transcriptional repression through interaction with HIF1A, HIF1AN and histone deacetylases. Ubiquitinates, in an oxygen-responsive manner, ADRB2 (By similarity).
Nucleotide accession_num
NM_052801.1
Protein accession_num
NP_434688.1
Protein name
von Hippel-Lindau disease tumor suppressor
Manufacturer - Specificity
This assay has high sensitivity and excellent specificity for detection of Von Hippel Lindau Tumor Suppressor (vHL).No significant cross-reactivity or interference between Von Hippel Lindau Tumor Suppressor (vHL) and analogues was observed.
Assay info
Assay Methodology: Quantitative Sandwich ELISA
Kit Components
Component: Amount
Anti-VHL Microplate: 96 Wells (12 x 8 Well strips)
VHL Lyophilized Standard: 2
100X Biotinylated VHL Detector Antibody: 1 x 120 uL
100X Avidin-HRP Conjugate: 1 x 120 uL
Standard Diluent: 1 x 20 mL
Detector Antibody Diluent: 1 x 12 mL
Conjugate Diluent: 1 x 12 mL
30X Wash Buffer: 1 x 20 mL
Stop Solution: 1 x 6 mL
TMB Substrate: 1 x 9 mL
Kit detection
Colorimetric
Kit duration
3h
Kit principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Von Hippel Lindau Tumor Suppressor (vHL). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Von Hippel Lindau Tumor Suppressor (vHL). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Von Hippel Lindau Tumor Suppressor (vHL), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm +/- 10nm. The concentration of Von Hippel Lindau Tumor Suppressor (vHL) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Kit reproducibility
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Von Hippel Lindau Tumor Suppressor (vHL) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Von Hippel Lindau Tumor Suppressor (vHL) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
Sample Type
Tissue homogenates and other biological fluids

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 96 Wells
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen