Vergleich

DOPA Decarboxylase/DDC ELISA Kit, human

ArtNr OCE-EK1238
Hersteller Bio-Ocean
Menge 96T
Kategorie
Typ Elisa-Kit
Applikationen ELISA
Specific against other
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Lieferbar
Description
This assay employs the quantitative sandwich enzyme immunoassay technique for the quantitative detection of human DDC. The Human DOPA Decarboxylase/DDC ELISA is for research use only. Not for diagnostic or therapeutic procedures. DOPA decarboxylase (DDC), also known as aromatic-L-amino acid decarboxylase, is a 54 kDa lyase enzyme. It is a vitamin B6-dependent homodimeric enzyme that catalyzes the decarboxylation of both L-3, 4 -dihydroxyphenylalanine (L-DOPA) and L-5-hydroxytryptophan (5-HTP) to dopamine and serotonin, respectively. In normal dopamine and serotonin neurotransmitter synthesis, DDC is not the rate-limiting step in either reaction. However, DDC becomes the rate-limiting step of dopamine synthesis in patients treated with L-DOPA (such as in Parkinson's Disease), and the rate-limiting step of serotonin synthesis in people treated with 5-HTP (such as in mild depression or dysthymia). DDC is inhibited by Carbidopa outside of the blood brain barrier to inhibit the premature conversion of L-DOPA to dopamine in the treatment of Parkinson's. In humans, DDC is also the rate-limiting enzyme in the formation of trace amine neurotransmitters. Deficiency of DDC is associated with various symptoms as severe developmental delay, oculogyric crises and autonomic dysfunction.
Components
96-well polystyrene microplate coated with a monoclonal antibody against DDC
Human DDC Standard, lyophilized
DDC Detect Antibody
Standard Diluent
Assay Buffer (10x)
Substrate (TMB)
Stop Solution
Washing Buffer (20x)
Plate Covers
Assay Type
Sandwich ELISA
Cross-Reactivity
Human
Suitable Sample Type
serum, plasma, cell culture supernates
Format
96-well strip plate
Storage
4C (unopened)
standard stored at -20C, others stored at 4C (opened)
Sample Volume
50 ul
Sensitivity
1.02 pg/ml
Standard Curve Range
468.75 - 30000 pg/ml
Spike Recovery Range
81 % - 103 %
Mean Spike Recovery
0, 92
Range of Sample Value of Normal Sera
n.d. - 18334.5 pg/ml
Detectable percentage of Normal Sera
37 % (n=30)
CV of Intra plate
2.0 % - 3.0 %
CV of Inter plate
2.3 % - 3.3 %

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 96T
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen