Vergleich

ELISA Kit for Angiotensin II (AngII)

ArtNr CEA005Mu-24T
Hersteller Cloud-Clone
Menge 24 T
Quantity options 10x96 T 24 T 48 T 5x96 T 96 T
Kategorie
Typ Elisa-Kit
Specific against Mouse (Murine, Mus musculus)
Sensitivity The minimum detectable dose of this kit is typically less than 8.84pg/mL
Citations Mesangial medium with IgA1 from IgA nephropathy inhibits nephrin expression in mouse podocytesEffect of aggregated immunoglobulin A1 from immunoglobulin A nephropathy patients on nephrin expression in podocytesBiglcan is beneficial in angiotensin II induced heart failure by preventing cardiac inflammation and remodeling improving LV function and mortality by preventing transdifferentiation of myofibroblastsCathepsin G deficiency reduces periaortic calcium chloride injury-induced abdominal aortic aneurysms in mice Administration of exogenous 1,25(OH)2D3 normalizes overactivation of the central renin-angiotensin system in 1α(OH)ase knockout miceA background Ca2+ entry pathway mediated by TRPC1/TRPC4 is critical for development of pathological cardiac remodellingEpigallocatechin-3-gallate Attenuates Renal Damage by Suppressing Oxidative Stress in Diabetic db/db MiceAngiotensin type 2 receptor null mice express reduced levels of renal angiotensin converting enzyme-2/angiotensin (1-7)/Mas receptor and exhibit greater high-fat diet-induced kidney injuryβ-Aminoisobutyric acid ameliorates the renal fibrosis in mouse obstructed kidneys via inhibitionof renal fibroblast activation and fibrosis.The Renin-Angiotensin System Regulates Neurodegeneration in a Mouse Model of Optic NeuritisEnhanced heart failure, mortality and renin activation in female mice with experimental dilated cardiomyopathyHydrogen Sulfide Attenuates Atherosclerosis in a Partially Ligated Carotid Artery Mouse model via Regulating Angiotensin Converting Enzyme 2 ExpressionBrain Renin–Angiotensin System Blockade Attenuates Methamphetamine-Induced Hyperlocomotion and NeurotoxicityALDH2 protects against alcoholic cardiomyopathy through a mechanism involving the p38 MAPK/CREB pathway and local renin-angiotensin system inhibition in …Angiotensin II enhances the proliferation of Natural Killer/T-cell lymphoma cells via activating PI3K/Akt signaling pathwayThe vascular endothelial growth factor trap aflibercept induces vascular dysfunction and hypertension via attenuation of eNOS/NO signaling in miceRenovascular effects of inorganic nitrate following ischemia-reperfusion of the kidneyAng-(1-7) Protects Skeletal Muscle Function in Aged MiceAng-(1–7) protects skeletal muscle function in aged miceTianma Gouteng Decoction regulates oxidative stress and inflammation in AngII-induced hypertensive mice via transcription factor EB to exert anti …
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias Ang-II,Angiotensin-2
Lieferbar
Specificity Mus musculus (Mouse)
Manufacturer - Applications
Enzyme-linked immunosorbent assay for Antigen Detection.
Manufacturer - Category
ELISA CLIA Kits
Sample type
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay length
2h
Method
Competitive Inhibition
Specificity

This assay has high sensitivity and excellent specificity for detection of Angiotensin II (AngII).

No significant cross-reactivity or interference between Angiotensin II (AngII) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Angiotensin II (AngII) were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Angiotensin II (AngII) were tested on 3 different plates, 8 replicates in each plate.

CV(%) = SD/meanX100

Intra-Assay: CV<10%

Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.

To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary
1. Prepare all reagents, samples and standards;

2. Add 50uL standard or sample to each well.

        And then add 50uL prepared Detection Reagent A immediately.

        Shake and mix. Incubate 1 hour at 37° C;

3. Aspirate and wash 3 times;

4. Add 100uL prepared Detection Reagent B. Incubate 30 minutes at 37° C;

5. Aspirate and wash 5 times;

6. Add 90uL Substrate Solution. Incubate 10-20 minutes at 37° C;

7. Add 50uL Stop Solution. Read at 450 nm immediately.
Test principle
This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Angiotensin II (AngII) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Angiotensin II (AngII) and unlabeled Angiotensin II (AngII) (Standards or samples) with the pre-coated antibody specific to Angiotensin II (AngII). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Angiotensin II (AngII) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Angiotensin II (AngII) in the sample.
Manufacturer - Research Area
Endocrinology; Cardiovascular biology

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 24 T
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen