ELISA Kit for B-Cell Leukemia/Lymphoma 2 (Bcl2)

ArtNr SEA778Hu-48T
Hersteller Cloud-Clone
Menge 48 Tests
Quantity options 10x96 Tests 24 Tests 48 Tests 5x96 Tests 96 Tests
Kategorie
Typ Elisa-Kit
Specific against Human (Homo sapiens)
Sensitivity The minimum detectable dose of this kit is typically less than 0.056ng/mL
Citations Analysis of p53 and miRNA expression after irradiation of glioblastoma cell linesSerum Bcl-2 Values in Children with Pulmonary HypertensionHepatoprotective Effects of Rubus idaeus L. Leaves against CCl4-Induced Liver Injury via Antioxidant, Anti-inflammatory and Antiapoptotic MechanismsDistinctive expression signatures of serum microRNAs in ischaemic stroke and transient ischaemic attack patientsAssociation of Bax and Bcl-2 Functional Polymorphisms and Protein Levels with Posttraumatic Stress DisorderStructural optimization and additional targets identification of antisense oligonucleotide G3139 encapsulated in a neutral cytidinyl-lipid combined with a cationic lipid …Effects of different pulp-capping materials on cell death signaling pathways of lipoteichoic acid-stimulated human dental pulp stem cellsPotential Therapeutic Effects of New Ruthenium (III) Complex with Quercetin: Characterization, Structure, Gene Regulation, and Antitumor and Anti-Inflammatory Studies (RuIII/Q Novel Complex Is a Potent Immunoprotective Agent)Expression of Apoptotic Markers Bcl-2 and Bax in the Vascular Wall
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias B-Cell CLL/Lymphoma 2
Lieferbar
Specificity Homo sapiens (Human)
Manufacturer - Applications
Enzyme-linked immunosorbent assay for Antigen Detection.
Manufacturer - Category
ELISA CLIA Kits
Sample type
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay length
3h
Method
Double-antibody Sandwich
Specificity

This assay has high sensitivity and excellent specificity for detection of B-Cell Leukemia/Lymphoma 2 (Bcl2).

No significant cross-reactivity or interference between B-Cell Leukemia/Lymphoma 2 (Bcl2) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level B-Cell Leukemia/Lymphoma 2 (Bcl2) were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level B-Cell Leukemia/Lymphoma 2 (Bcl2) were tested on 3 different plates, 8 replicates in each plate.

CV(%) = SD/meanX100

Intra-Assay: CV<10%

Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.

To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary
1. Prepare all reagents, samples and standards;

2. Add 100uL standard or sample to each well. Incubate 2 hours at 37° C;

3. Aspirate and add 100uL prepared Detection Reagent A. Incubate 1 hour at 37° C;

4. Aspirate and wash 3 times;

5. Add 100uL prepared Detection Reagent B. Incubate 30 minutes at 37° C;

6. Aspirate and wash 5 times;

7. Add 90uL Substrate Solution. Incubate 10-20 minutes at 37° C;

8. Add 50uL Stop Solution. Read at 450nm immediately.
Test principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to B-Cell Leukemia/Lymphoma 2 (Bcl2). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to B-Cell Leukemia/Lymphoma 2 (Bcl2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain B-Cell Leukemia/Lymphoma 2 (Bcl2), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of B-Cell Leukemia/Lymphoma 2 (Bcl2) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Manufacturer - Research Area
Signal transduction; Apoptosis;

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 48 Tests
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen