Specific against Cow (Bos taurus), Cattle (Bovine)
Sensitivity The minimum detectable dose of this kit is typically less than 1.28ng/mL
Citations Oral administration of heat-inactivated Mycobacterium bovis reduces the response of farmed red deer to avian and bovine tuberculin
Comparative proteomics of milk fat globule membrane in goat colostrum and mature milk
The response of red deer to oral administration of heat-inactivated Mycobacterium bovis and challenge with a field strain.
The bovine cumulus proteome is influenced by maturation condition and maturational competence of the oocyte
Effect of alfalfa hay and starter feed supplementation on caecal microbiota and fermentation, growth, and health of yak calves
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias ASP,CPAMD1,Complement Protein C3,C3 and PZP-like alpha-2-macroglobulin domain-containing protein 1,C3a anaphylatoxin,Acylation stimulating protein
Lieferbar
Specificity Bos taurus; Bovine (Cattle)
Manufacturer - Applications
Enzyme-linked immunosorbent assay for Antigen Detection.
Manufacturer - Category
ELISA CLIA Kits
Sample type
Serum, plasma and other biological fluids
Assay length
3h
Method
Double-antibody Sandwich
Specificity

This assay has high sensitivity and excellent specificity for detection of Complement Component 3 (C3).

No significant cross-reactivity or interference between Complement Component 3 (C3) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Complement Component 3 (C3) were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Complement Component 3 (C3) were tested on 3 different plates, 8 replicates in each plate.

CV(%) = SD/meanX100

Intra-Assay: CV<10%

Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.

To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary
1. Prepare all reagents, samples and standards;

2. Add 50uL standard or sample to each well.

        And then add 50uL prepared Detection Reagent A immediately.

        Shake and mix. Incubate 1 hour at 37° C;

3. Aspirate and wash 3 times;

4. Add 100uL prepared Detection Reagent B. Incubate 30 minutes at 37° C;

5. Aspirate and wash 5 times;

6. Add 90uL Substrate Solution. Incubate 10-20 minutes at 37° C;

7. Add 50uL Stop Solution. Read at 450 nm immediately.
Test principle
This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Complement Component 3 (C3) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Complement Component 3 (C3) and unlabeled Complement Component 3 (C3) (Standards or samples) with the pre-coated antibody specific to Complement Component 3 (C3). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Complement Component 3 (C3) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Complement Component 3 (C3) in the sample.
Manufacturer - Research Area
Signal transduction; Infection immunity; Immune molecule;

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 96 Tests
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen