Vergleich

ELISA Kit for Serotonin Transporter (SERT)

ArtNr SEC890Ra-96T
Hersteller Cloud-Clone
Menge 96 Tests
Quantity options 10x96 Tests 24 Tests 48 Tests 5x96 Tests 96 Tests
Kategorie
Typ Elisa-Kit
Specific against Rat (Rattus norvegicus)
Sensitivity The minimum detectable dose of this kit is typically less than 0.057ng/mL
Citations Neurotoxicity and inflammation induced by individual and combined exposure to iron oxide nanoparticles and silver nanoparticles
Effects of regulating gut microbiota on the serotonin metabolism in the chronic unpredictable mild stress rat model
Neuronal Cell Death Induces Depressive Disorder in Rats Depression-Like Behaviors Caused by Chronic Stress
Administration of a Probiotic Mixture Ameliorates Cisplatin-Induced Mucositis and Pica by Regulating 5-HT in Rats
Targeting the oxytocin system to ameliorate early life depressive-like behaviors in maternally-separated rats
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias SLC6A4,SLC6-A4,HTT,5-HTT,5HTT,OCD1,hSERT,Solute Carrier Family 6,Member 4,Neurotransmitter Transporter,Serotonin,Sodium-dependent serotonin transporter
Lieferbar
Specificity Rattus norvegicus (Rat)
Manufacturer - Applications
Enzyme-linked immunosorbent assay for Antigen Detection.
Manufacturer - Category
ELISA CLIA Kits
Sample type
tissue homogenates, cell lysates and other biological fluids
Assay length
3h
Method
Double-antibody Sandwich
Specificity

This assay has high sensitivity and excellent specificity for detection of Serotonin Transporter (SERT).

No significant cross-reactivity or interference between Serotonin Transporter (SERT) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Serotonin Transporter (SERT) were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Serotonin Transporter (SERT) were tested on 3 different plates, 8 replicates in each plate.

CV(%) = SD/meanX100

Intra-Assay: CV<10%

Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.

To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary
1. Prepare all reagents, samples and standards;

2. Add 100uL standard or sample to each well. Incubate 2 hours at 37° C;

3. Aspirate and add 100uL prepared Detection Reagent A. Incubate 1 hour at 37° C;

4. Aspirate and wash 3 times;

5. Add 100uL prepared Detection Reagent B. Incubate 30 minutes at 37° C;

6. Aspirate and wash 5 times;

7. Add 90uL Substrate Solution. Incubate 10-20 minutes at 37° C;

8. Add 50uL Stop Solution. Read at 450nm immediately.
Test principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Serotonin Transporter (SERT). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Serotonin Transporter (SERT). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Serotonin Transporter (SERT), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Serotonin Transporter (SERT) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Manufacturer - Research Area
Neuro science;

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 96 Tests
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen