Vergleich

ELISA Kit for Beclin 1 (BECN1)

ArtNr SEJ557Hu-96T
Hersteller Cloud-Clone
Menge 96 T
Quantity options 10x96 T 24 T 48 T 5x96 T 96 T
Kategorie
Typ Elisa-Kit
Specific against Human (Homo sapiens)
Sensitivity The minimum detectable dose of this kit is typically less than 0.054ng/mL
Citations Can Enhanced Autophagy be Associated with Human Longevity? Serum Levels of the Autophagy Biomarker Beclin-1 are Increased in Healthy Centenarians
A peel-off facial mask comprising myoinositol and trehalose-loaded liposomes improves adult female acne by reducing local hyperandrogenism and activating autophagy
The novel CXCR4 antagonist, PRX177561, reduces tumor cell proliferation and accelerates cancer stem cell differentiation in glioblastoma preclinical models
Beclin1 circulating levels and accelerated ageing markers in COPD
Beclin1 circulating levels and accelerated aging markers in COPD
A novel combined score of biomarkers in sputum may be an indicator for lung cancer: A pilot study
Serum concentration of autophagy-related protein 7 is correlated with non-alcoholic fatty liver disease in Chinese adults
Crosstalk between vitamin D axis, inflammation and host immunity mechanisms: A prospective study
Inhibition of HepG-2 Cells (Liver Cancer Cell Line) Viability by 3-Hydroxypyridine-2-Carboxaldehyde N (4)-Methylthiosemicarbazone
BIOMARKERS OF AUTOPHAGY AND ANTIVIRAL ROLE OF PLACENTA FOR PREDICTING PRETERM DELIVERY IN PATIENTS WITH PRETERM DELIVERY?¡­
IDENTIFICATION OF FACTORS CONNECTED WITH AUTOPHAGY ACTIVITY UNDER CONDITIONS OF PARTIAL NUTRITIONAL DEPRIVATION IN MEN
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias ATG6,VPS30,Coiled-Coil,Myosin-Like BCL2 Interacting Protein,ATG6 Autophagy Related 6 Homolog
Lieferbar
Specificity Homo sapiens (Human)
Manufacturer - Applications
Enzyme-linked immunosorbent assay for Antigen Detection.
Manufacturer - Category
ELISA CLIA Kits
Sample type
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay length
3h
Method
Double-antibody Sandwich
Specificity

This assay has high sensitivity and excellent specificity for detection of Beclin 1 (BECN1).

No significant cross-reactivity or interference between Beclin 1 (BECN1) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Beclin 1 (BECN1) were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Beclin 1 (BECN1) were tested on 3 different plates, 8 replicates in each plate.

CV(%) = SD/meanX100

Intra-Assay: CV<10%

Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.

To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary
1. Prepare all reagents, samples and standards;

2. Add 100uL standard or sample to each well. Incubate 2 hours at 37° C;

3. Aspirate and add 100uL prepared Detection Reagent A. Incubate 1 hour at 37° C;

4. Aspirate and wash 3 times;

5. Add 100uL prepared Detection Reagent B. Incubate 30 minutes at 37° C;

6. Aspirate and wash 5 times;

7. Add 90uL Substrate Solution. Incubate 10-20 minutes at 37° C;

8. Add 50uL Stop Solution. Read at 450nm immediately.
Test principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Beclin 1 (BECN1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Beclin 1 (BECN1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Beclin 1 (BECN1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Beclin 1 (BECN1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Manufacturer - Research Area
Infection immunity;

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 96 T
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen