Vergleich

ELISA Kit for High Temperature Requirement Factor A1 (HTRA1)

ArtNr SEL604Hu-5x96T
Hersteller Cloud-Clone
Menge 5x96 T
Quantity options 10x96 T 24 T 48 T 5x96 T 96 T
Kategorie
Typ Elisa-Kit
Specific against Human (Homo sapiens)
Sensitivity The minimum detectable dose of this kit is typically less than 13.2pg/mL
Citations Alterations of maternal plasma HTRA1 level in preeclampsia complicated by IUGR
Upregulation of HtrA4 in the placentas of patients with severe pre-eclampsia
Association of frailty with the serine protease HtrA1 in older adults
HtrA1 up-regulates expression of MMPs via Erk1/2/Rock-dependent pathways
Association between first trimester plasma htra1 level and subsequent preeclampsia: a possible early marker?
First trimester HtrA1 maternal plasma level and spontaneous preterm birth
Cross-sectional associations among P3NP, HtrA, Hsp70, Apelin and sarcopenia in Taiwanese population
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias HtrA,L56,ORF480,PRSS11,HtrA Serine Peptidase 1,Protease,Serine,11,IGFBP5-Protease,High-temperature requirement A serine peptidase 1
Lieferbar
Specificity Homo sapiens (Human)
Manufacturer - Applications
Enzyme-linked immunosorbent assay for Antigen Detection.
Manufacturer - Category
ELISA CLIA Kits
Sample type
serum, plasma and other biological fluids
Assay length
3h
Method
Double-antibody Sandwich
Specificity

This assay has high sensitivity and excellent specificity for detection of High Temperature Requirement Factor A1 (HTRA1).

No significant cross-reactivity or interference between High Temperature Requirement Factor A1 (HTRA1) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Temperature Requirement Factor A1 (HTRA1) were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Temperature Requirement Factor A1 (HTRA1) were tested on 3 different plates, 8 replicates in each plate.

CV(%) = SD/meanX100

Intra-Assay: CV<10%

Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.

To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary
1. Prepare all reagents, samples and standards;

2. Add 100uL standard or sample to each well. Incubate 2 hours at 37° C;

3. Aspirate and add 100uL prepared Detection Reagent A. Incubate 1 hour at 37° C;

4. Aspirate and wash 3 times;

5. Add 100uL prepared Detection Reagent B. Incubate 30 minutes at 37° C;

6. Aspirate and wash 5 times;

7. Add 90uL Substrate Solution. Incubate 10-20 minutes at 37° C;

8. Add 50uL Stop Solution. Read at 450nm immediately.
Test principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to High Temperature Requirement Factor A1 (HTRA1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to High Temperature Requirement Factor A1 (HTRA1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain High Temperature Requirement Factor A1 (HTRA1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of High Temperature Requirement Factor A1 (HTRA1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Manufacturer - Research Area
Enzyme & Kinase;

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 5x96 T
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen