Vergleich

Gelatin Zymography Kit (Cosmo Bio type: narrow thin plates)

ArtNr PMC-AK47
Hersteller Cosmobio
Menge 1 Kit
Kategorie
Typ Kit
Specific against other
ECLASS 10.1 32161090
ECLASS 11.0 32161090
UNSPSC 41116126
Lieferbar
Manufacturer - Category
Research Area/Cell Biology/Extracellular Matrix/Zymography; Assays/Extracellular Matrix/Zymography; Assays/Zymography
Maker
PMC
Description
Matrix metalloproteinases (MMPs) belong to the family of metalloproteinases, which consists of at least 20 members, and known to be involved in the metabolism of extracellular matrix proteins. MMPs are widely detected by zymography. The Gelatin-Zymography Kit (Cat.No.AK47-COS and AK45-COS) provides an easy system of the electrophoresis for zymography. This product is used for detecting ProMMP-2, MMP-2 and ProMMP-9 in blood, body fluid, secretion, cell lysate, cell culture medium, and other samples.
Our Zymography precast gels are available in two types (sizes). Please choose the type that fits your gel box.
ATTO type: Glass plate gel is 120(W)× 100(H) and the thickness is 1mm
Cosmo Bio type: Glass plate gel is 100(W)× 100(H) and the thickness is 1mm.
Zymography Kit provides an easy system of the electrophoresis for zymography. This product is used for detecting ProMMP-2, MMP-2 and ProMMP-9 in blood, body fluid, secretion, cell lysate, cell culture medium, and other samples. [Cautions: This product has a short expiration date (less than 3 months). Please use it after arrival as soon as possible.
Protocol:
1. Load 100-150 mL of Electrophoresis Buffer to the lower chamber (anode). Refer to the instruction manual ofyour electrophoresis tank/chamber to know appropriate volume of the buffer.
2. Take out the comb on precast gel carefully and set the gel to electrophoresis chamber. The side of sample holes should be set on the upper side. If the sample holes aredisturbed, fix them up with needle etc.
3. Load around 100 mL of Electrophoresis Buffer to the upper chamber (cathode).
4. Mixsamples with equivalent volume of sample preparation buffer. Incubate for 15 minutes at Room Temperature. (Do NOT heat thesamples.)
*MMP markers can be used without sample preparation buffer.
5. Apply the samples and MMP markers to gel plate.
6.Run electrophoresis at 15 mA constant current. (If you use 2 gels, set the current at 30 mA)
7. After the run is completed, turn off the electrophoresis chamber, and take out the gel plate from the chamber.
8. Remove the upper glass plate of thegel plate and peel off the gel carefully with a spatula.
9. Put the gel in the tray with 200 ml of Washing Buffer. Incubate with shaking at Room Temperature.
10. Put the gel in the container with 50 ml of Reaction Buffer and seal up the container. Incubate the gel in the container in incubator at 37° C for 20-40 hrs (Lower enzyme concentration needs longer reaction time.).
11. After enzymatic reaction, put the gel in the container with Staining solution. Incubate for 30 minutes at Room Temperature to stain protein.
12. Put the gel in the container with De-staining solution. And incubate for 30 minutes to several hours to de-stain.
Gelatin Zymography Kit provides an easy system of the electrophoresis for zymography. This product is used for detecting ProMMP-2, MMP-2 and ProMMP-9 in blood, body fluid, secretion, cell lysate, cell culture medium, and other samples. [Cautions: This product has a short expiration date (less than 3 months). Please use it after arrival as soon as possible.


Citations


  • Jong Youl Kim, Nuri Kim, Zhen Zheng, Jong Eun Lee, and Midori A. Yenari
    The 70kD heat shock protein protects against experimental traumatic brain injury
    Neurobiol Dis. 2013 October ; 58: 289– 295. PMID: 23816752

  • Yang Zheng, Seiji Yamamoto, Yoko Ishii, Yang Sang, Takeru Hamashima, Nguyen Van De, Hirofumi Nishizono, Ran Inoue, Hisashi Mori, and Masakiyo Sasahara
    Glioma-Derived Platelet-Derived Growth Factor-BB Recruits Oligodendrocyte Progenitor Cells via Platelet-Derived Growth Factor Receptor-a and Remodels Cancer Stroma
    The American Journal of Pathology, Vol. 186, No. 5, May 2016 PMID: 26945107




References


  • Miyazaki, K., Ohta, Y., Nagai, M., Morimoto, N., Kurata, T., Takehisa, Y., Ikeda, Y., Matsuura, T., Abe, K.
    Disruption of Neurovascular Unit Prior to Motor Neuron Degeneration in Amyotrophic Lateral Sclerosis.
    J. Neurosci. Res. 89, 718-728 (2011)
    PMID: 21337372

  • Fujiwara, M., Kashima, T. G., Kunita, A., Kii, I., Komura, D., Grigoriadis, A. E., Kudo, A., Aburatani, H., Fukayama, M.
    Stable Knockdown of S100A4 Suppresses Cell Migration and Metastasis of Osteosarcoma.
    Tumour Biol. 2011 Jun; 32(3):611-22.
    PMID: 21360024

  • Aoki, T., Kataoka, H., Ishibashi, R., Nozaki, K., Hashimoto, N.
    Simvastatin Suppresses the Progression of Experimentally Induced Cerebral Aneurysms in Rats.
    Stroke. 39, 1276-85 (2008) PMID: 18309148

  • Kuramochi, D., Unoki, H., Bujo, H., Kubota, Y., Jiang, M., Rikihisa, N., Udagawa, A., Yoshimoto, S., Ichinose, M., Saito, Y.
    Matrix Metalloproteinase 2 Improves The Transplanted Adipocyte Survival in Mice.
    Eur. J. Clin. Invest. 38, 752-759 (2008) PMID: 18837800

  • Fujimoto, M., Takagi, Y., Aoki, T., Hayase, M., Marumo, T., Gomi, M., Nishimura, M., Kataoka, H., Hashimoto, N., Nozaki, K.
    Tissue Inhibitor of Metalloproteinases Protect Blood-brain Barrier Disruption in Focal Cerebral Ischemia.
    J. Cereb. Blood Flow Metab. 28, 1674-1685 (2008) PMID: 18560439

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: 1 Kit
Lieferbar: In stock
lieferbar

Vergleichen

Auf den Wunschzettel

Angebot anfordern

Lieferzeit anfragen

Technische Frage stellen

Bulk-Anfrage stellen

Fragen zum Produkt?
 
Schließen