Description |
The Alpha-1-Antitrypsin (a1AT) BioAssay™ ELISA Kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of a1AT in human serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Detection Range: 6.25-400ng/ml
Sensitivity: 2.83ng/ml
Intra-Assay: CV: <10%
Inter-Assay: CV: <12%
Kit Components: *023260A: Microtiter Strips, 1x96 wells, Pre-coated, ready to use *023260B: Standard, 2x1 vial 023260C: Standard Diluent, 1x20ml *023260D: Detection Reagent A (green), 1x120ul *023260E: Detection Reagent B (red), 1x120ul 023260F: Assay Diluent A, 1x12ml 023260G: Assay Diluent B, 1x12ml 023260H: TMB Substrate, 1x9ml *023260J: Positive Control, 41.13ng/ml, 1x1vial (Lyophilized) 023260K: Stop Solution, 1x6ml 023260L: Wash Buffer, 30X, 1x20ml
Precaution: The Stop Solution (023260K) included for use in this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
Storage and Stability: Store *023260A, *023260B, *023260D, *023260E and *023260J at -20°C. After reconstitution of *023260J, store at 4°C and use within 5 days. Store all the other components at 4°C. Unused kit is stable for 6 months after receipt. Once kit components are opened, it is highly recommended to use remaining reagents within 1 month provided this is within the expiration date of the kit. For maximum recovery of product, centrifuge the original vials after thawing and prior to removing the cap.
Notes on 023260J - Positive Control: Intended Use: The control vials are from a human serum sample known to contain the target protein. It will provide a positive result in the ELISA assay, which indicates that the kit is optimized and working properly.
Characteristics: The control vials contain human a1AT in human serum (lyophilized powder). Note: The human based serum used in this product are screened for HIV, Hepatitis A, B, C, HTLV and Syphilis.
Expected Value: 146.2ng/ml
Usage: Dissolve with 150ul standard diluent and let stand for 10 minutes. Mix gently before use. In the experiment, add 100ul to an appropriate well of the plate and test its concentration along with standards and samples. Note: Upon receipt store Positive Control vial at -20°C. After reconstitution, store Positive Control vial at 4°C and use within 5 days.
Assay Procedure Summary: 1. Prepare all reagents, samples and standards. 2. Add 100ul standard or sample to each well. Incubate 1 hour at 37°C. 3. Aspirate and add 100ul prepared Detection Reagent A. Incubate 1 hour at 37°C. 4. Aspirate and wash 3 times. 5. Add 100ul prepared Detection Reagent B. Incubate 30 minutes at 37°C. 6. Aspirate and wash 5 times. 7. Add 90ul Substrate Solution. Incubate 10-20 minutes at 37°C. 8. Add 50ul Stop Solution. Read at 450nm immediately. |