Description |
Carbonic Anhydrase IX (CA9) BioAssay™ ELISA Kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of CA9 in mouse serum, plasma, tissue homogenates and other biological fluids.
Detection Range: 1.56-100pg/ml
Sensitivity: 0.59pg/ml
Intra-Assay CV: <10%
Inter-Assay CV: <12%
Kit Components: *023906A: Microtiter Strips, 1x48 wells or 1x96 wells, Pre-coated, ready to use *023906B: Standard, 2x1 vial 023906C: Standard Diluent, 1x10ml or 1x20ml *023906D: Detection Reagent A (green), 1x60ul or 1x120ul *023906E: Detection Reagent B (red), 1x60ul or 1x120ul 023906F: Assay Diluent A, 1x6ml or 1x12ml 023906G: Assay Diluent B, 1x6ml or 1x12ml 023906H: TMB Substrate, 1x4.5ml or 1x9ml *023906J: Positive Control, 23.7pg/ml, 1x1vial 023906K: Stop Solution, 1x3ml or 1x6ml 023906L: Wash Buffer, 30X, 1x10ml or 1x20ml
Precaution: The Stop Solution (023906K) included for use in this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
Storage and Stability: Store *023906A, *023906B, *023906D, *023906E and *023906J at -20°C. Store all the other components at 4°C. After reconstitution of *023906J, store at 4°C and use within 5 days. Unused kit is stable for 6 months after receipt. Once kit components are opened, it is highly recommended to use remaining reagents within 1 month provided this is within the expiration date of the kit. For maximum recovery of product, centrifuge the original vials after thawing and prior to removing the cap.
Notes on 023906J: Positive Control:
Intended Use: The control vial is from a mouse serum sample known to contain the target protein. It will provide a positive result in the ELISA assay, which indicates that the kit is optimized and working properly.
Characteristics: The control vial contains mouse CA9 in mouse serum (lyophilized powder). Note: The mouse source material used in this product is from healthy mouse of SPF standards (specific pathogen-free animals).
Expected Values: 23.7pg/ml
Usage: Dissolve with 150ul standard diluent and let it stand for 10 minutes. If powder is partly insoluble, shake gently until fully dissolved. Mix gently before use. In the experiment, add 100ul to an appropriate well of the plate and test its concentration along with standards and your specimens. Note: Upon receipt store Positive Control vial at -20°C. After reconstitution, store Positive Control vial at 4°C and use within 5 days.
Assay Procedure Summary: 1. Prepare all reagents, samples and standards. 2. Add 100ul standard or sample to each well. Incubate 2 hours at 37°C. 3. Aspirate and add 100ul prepared Detection Reagent A. Incubate 1 hour at 37°C. 4. Aspirate and wash 3 times. 5. Add 100ul prepared Detection Reagent B. Incubate 30 minutes at 37°C. 6. Aspirate and wash 5 times. 7. Add 90ul Substrate Solution. Incubate 15-25 minutes at 37°C. 8. Add 50ul Stop Solution. Read at 450nm immediately. |