Comparison

Gold-in-a-Box Conjugation Kit, 40 nm, 100 mL

Item no. NGIB40-B100
Manufacturer Bioassay Works
Amount 100 mL
Category
Type Beads Based kits
Specific against other
ECLASS 10.1 32161000
ECLASS 11.0 32161000
UNSPSC 41116126
Available
Description
The Gold-in-a-Box Conjugation Kit, 40 nm, contains the reagents required to prepare highly-reactive antibody or soluble protein gold conjugates that can be utilized in lateral-flow assays.
The key to most high-performance lateral-flow assays is the ability to covalently attach antibodies/proteins to gold nanoparticles. The Gold-in-a-Box Conjugation Kit enables optimal binding of an antibody/protein to our Naked Gold 40 nm highly concentrated gold sol, while retaining a high degree of specific activity through adjusting the pH of the gold sols to slightly above the isoelectric point of the coating antibody/protein. This is done through a series of pH titrations with the provided buffers. The Gold-in-a-Box kit allows researchers and assay developers to quickly (in less than 50 minutes) determine the pI and optimal coating conditions for your antibody or soluble protein and to perform the conjugation reaction. A sample preparation and gold conjugation procedure is provided.
Reagents are also provided to coat the resultant gold conjugates on polyester of glass fiber ribbon.

Kit Contents:

NG40-B100 – Naked Gold 40 nm Concentrated Gold Sol at 15 O.D./mL, 100 mL
BUFA-001 – Buffer Solution A, 1.0 mL
BUFB-001 – Buffer Solution B, 1.0 mL
BUFC-001 – Buffer Solution C, 1.0 mL
BUFD-001 – Buffer Solution D, 1.0 mL
BLK-005 – BSA Blocking Stabilizer Solution, 5.0 mL
CDB-005 – Gold Drying Buffer, 5.0 mL
Weight
.6 lbs
Dimensions
7 x 4.5 x 3.5 in
Storage Temperature
Refrigerated (2-8C), do not freeze
Shipping Temperature
Ambient temperatures
Stability
2 years from date of manufacture
References
Victoria Martinez-Sernandez, Laura Muino, Maria Jesus Perteguer, Teresa Garate, Mercedes Mezo, Marta Gonzalez-Warleta, Antonio Muro, Jose Manuel Correia da Costa, Fernanda Romaris, Florencio M. Ubeira. Development and Evaluation of a New Lateral Flow Immunoassay for Serodiagnosis of Human Fasciolosis. 2011.

Giyoung Kim, Ji-Hea Moon, Saet Byeol Park, Youn-Jung Jang, Jongguk Lim, Changyeun Mo. Image Analysis of a Lateral Flow Strip Sensor for the Detection of Escherichia coli O157:H7. Journal of Biosystems Engineering. 2013; 38(4): 335-340.

Sangdae Lee, Giyoung Kim and Jihea Moon. Performance Improvement of the One-Dot Lateral Flow Immunoassay for Aflatoxin B1 by Using a Smartphone-Based Reading System. Sensors. 2013; 13(4): 5109-5116.

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 100 mL
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?
 
Close