Comparison

Human P-Selectin / CD62P PicoKine® Quick ELISA Kit European Partner

Item no. BOS-FEK0505
Manufacturer Boster
Amount 96 wells/kit, with removable strips.
Category
Type Elisa-Kit
Applications ELISA
Specific against Human (Homo sapiens)
Sensitivity <5 pg/ml
Sequence Belongs to the selectin/LECAM family.
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias P-selectin,CD62 antigen-like family member P,Granule membrane protein 140,GMP-140,Leukocyte-endothelial cell adhesion molecule 3,LECAM3,Platelet activation dependent granule-external membrane protein,PADGEM,CD62P,SELP,GMRP,GRMP
Available
Manufacturer - Category
Quick ELISA Kits
Storage Conditions
Store at 4°C for 6 months. (Ships with gel ice, can store for up to 3 days in room temperature. Refrigerate upon receipt.)
Calculated Molecular weight
90834 MW
Gene Name
SELP
Gene Full Name
P-selectin
Manufacturer - Specificity
Natural and recombinant Human SELP
Background
P-selectin, also called GMP-140, CD62, or selectin P, is a 140-kD adhesion molecule, expressed at the surface of activated cells, that mediates the interaction of activated endothelial cells or platelets with leukocytes. It is stored in secretory granules and expressed at the plasma membrane after cell activation. It is known to play an important role in atherosclerosis. The major ligand for P-selectin on leukocytes is P-selectin glycoprotein ligand-1 (PSGL-1). The standard product used in this kit is recombinant human P-Selectin, excluding intercellular P-Selectin and transmembrane domain. It has 730 amino acids sequence with the molecular mass of 80 KDa.
Immunogen
Expression system for standard: NS0; Immunogen sequence: W42-A771
Protein Name
P-selectin
Protein Function
Ca (2+)-dependent receptor for myeloid cells that binds to carbohydrates on neutrophils and monocytes. Mediates the interaction of activated endothelial cells or platelets with leukocytes. The ligand recognized is sialyl-Lewis X. Mediates rapid rolling of leukocyte rolling over vascular surfaces during the initial steps in inflammation through interaction with PSGL1.
Subcellular Localization
Membrane; Single-pass type I membrane protein.
Description
Human P-Selectin / CD62P PicoKine® Quick ELISA Kit (90 minutes, 96 Tests). Quantitate Human SELP in cell culture supernatants, serum and plasma (heparin, EDTA, citrate). Sensitivity: 5pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Tissue Specificity
Stored in the alpha-granules of platelets and Weibel-Palade bodies of endothelial cells. Upon cell activation by agonists, P-selectin is transported rapidly to the cell surface.
Sample Type
cell culture supernatants, serum and plasma (heparin, EDTA, citrate)
Sequence Similarities
Belongs to the selectin/LECAM family.
Sample Data
Concentration (pg/ml) | 0 | 156 | 312 | 625 | 1250 | 2500 | 5000 | 10000
O.D. | 0.030 | 0.338 | 0.629 | 1.146 | 1.876 | 2.351 | 2.300 | 2.348
Intra Assay Consistency & Inter Assay Consistency
Intra-Assay Precision | Inter-Assay Precision
Sample | 1 | 2 | 3 | 1 | 2 | 3
n | 16 | 16 | 16 | 24 | 24 | 24
Mean (pg/ml) | 322 | 1820 | 5020 | 331 | 1849 | 5389
Standard deviation | 15.63 | 121.94 | 256.02 | 21.18 | 144.22 | 301.78
CV (%) | 4.7% | 6.7% | 5.6% | 6.4% | 7.8% | 5.6%
Reproducibility
Lots | Lot 1 (pg/ml) | Lot 2 (pg/ml) | Lot 3 (pg/ml) | Lot 4 (pg/ml) | Mean (pg/ml) | Standard Deviation | CV (%)
Sample 1 | 322 | 316 | 323 | 357 | 329 | 16.1 | 4.8%
Sample 2 | 1820 | 1756 | 2051 | 1775 | 1850 | 118.06 | 6.3%
Sample 3 | 5020 | 5825 | 5171 | 5716 | 5433 | 343.86 | 6.3%
*number of samples for each test n=16.
Capture antibody and Detection antibody
polyclonal antibody from goat|polyclonal antibody from goat
Kit Components
Description|Quantity|Volume
Anti-tag Pre-coated 96-well Strip Microplate|1|12 strips of 8 wells
Standard||2
Antibody A|1|3ml
Antibody B|1|3ml
Sample Diluent|1|15ml
TBS-T Wash Buffer (25x)|1|12ml
Color Developing Reagent (TMB)|1|10ml
Stop Solution|1|10ml
Adhesive Plate Sealers|2|Piece
Standard
10 ng/tube
Anticoagulant
heparin, EDTA or citrate
Material Required But Not Provided
Microplate Reader capable of reading absorbance at 450nm.
Automated plate washer (optional)
Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions.
Multichannel pipettes are recommended for large amount of samples.
Deionized or distilled water.
500ml graduated cylinders.
Test tubes for dilution.
Horizontal orbital microplate shaker capable of maintaining a speed of 500 rpm, amplitude 3mm.
Manufacturer - Cross Reactivity
There is no detectable cross-reactivity with other relevant proteins.

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 96 wells/kit, with removable strips.
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request