Comparison

Mini Samples Rat G Protein Coupled Receptor 131 (GPR131) ELISA Kit

Manufacturer Biomatik
Category
Type Elisa-Kit
Specific against Rat
Applications ELISA
Amount 96T
Item no. BM-EKU11129
Targets ADRA1A;;GPBAR1
eClass 6.1 32160605
eClass 9.0 32160605
Available
Format
96-Well Plate
Target Name
G Protein Coupled Receptor 131
Target Synonyms
GPBAR1; GPCR; BG37; GPCR19; M-BAR; TGR5; G Protein-Coupled Bile Acid Receptor 1; G-protein coupled receptor GPCR19; Membrane-type receptor for bile acids
Sample type
Tissue homogenates, cell lysates and other biological fluids
Detection ra nge
0.625-40 ng/mL
Sensitivity
0.231 ng/mL
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples G Protein Coupled Receptor 131 (GPR131) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples G Protein Coupled Receptor 131 (GPR131) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100. Intra-assay: CV<10%. Inter-Assay: CV<12%.
Detection Method
Colorimetric
Assay Time
3 hours
Assay Type
Double-antibody Sandwich
Shipping Condition
Ice packs
Storage
Short term: 4CC; Long term: see manual.
Precaution of Use
The Stop Solution is acidic. Do not allow to contact skin or eyes.
Expiry Date
8 months
UniProt ID
n/a
Specificity
This assay has high sensitivity and excellent specificity for detection of Mini Samples G Protein Coupled Receptor 131 (GPR131).
Cross Activity
This assay has high sensitivity and excellent specificity for detection of Mini Samples G Protein Coupled Receptor 131 (GPR131).
Test principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mini Samples G Protein Coupled Receptor 131 (GPR131). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Mini Samples G Protein Coupled Receptor 131 (GPR131). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mini Samples G Protein Coupled Receptor 131 (GPR131), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mini Samples G Protein Coupled Receptor 131 (GPR131) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Assay procedure summary
1. Prepare all reagents, samples and standards; 2. Add 25 uL standard or sample to each well. Incubate 1 hour at 37CC; 3. Aspirate and add 25 uL prepared Detection Reagent A. Incubate 1 hour at 37CC; 4. Aspirate and wash 3 times; 5. Add 25 uL prepared Detection Reagent B. Incubate 30 minutes at 37CC; 6. Aspirate and wash 5 times; 7. Add 25 uL Substrate Solution. Incubate 10-20 minutes at 37CC; 8. Add 20 uL Stop Solution. Read at 450nm immediately.
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Restrictions
For Research Use Only. Not for use in diagnostic procedures, drug use, or for administration to humans or animals.
Quality Systems
The kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
Quality Assurance
Biomatik ELISA Kits are not typically pre-assembled as finished products due to limited shelf life. Before shipping, each kit is assembled and tested to ensure that it meets specifications before shipping. Minor changes may occur to the Detection Range, Sensitivity, and Precision. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation. Please always refer to the hard copy manual included in The kitbefore experiment.

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 96T
Available: In stock
available

Delivery expected until 5/30/2024 

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?
 