Myoglobin Assay Kit Europäischer Partner

ArtNr abx098448-8
Hersteller Abbexa
Menge Hitachi 7170; R1: 60mlx3 R2: 15mlx3
Quantity options Toshiba 40; R1: 40mlx4 R2: 40mlx1 Hitachi 7020; R1: 40mlx4 R2: 40mlx1 Hitachi 7060; R1: 90mlx2 R2: 45mlx1 Hitachi 7170; R1: 60mlx3 R2: 15mlx3 Hitachi 7170; R1: 60mlx3 R2: 45mlx1
Kategorie
Typ Reagents
Format Liquid
Specific against other
ECLASS 10.1 42051003
ECLASS 11.0 42051003
UNSPSC 12000000
Lieferbar
Storage Conditions
Stored for up to 12 months at 2 - 8C, protect from light. After opening, the reagent remains stable for 30 days at 2 - 8C, protect from light.
Description
Myoglobin Assay Kit is an Assay Kit by Latex Enhanced Immunoturbidimetry Method.

Based on the bottle type, product model can be classified in to Hitachi 7170, Hitachi 7060, Hitachi 7020, Beckman, Toshiba, Mindray, DuPont, Innova, Siemens, KHB, Abbott, Universal types, etc

This reagent is used to determine the m yoglobin content in human serum.

The Mb in human serum or pla sm a meets its corresponding polyclonal and monoclonal antibodies respectively combined with latex particles in a liquid buffer, then the latex particles are cr oss - linked to each other and increase turbidity of the soluti on. Under a certain wavelength, t he turbidity is proportional to the concentration of Mb in the sample with the presence of an appropriate amount of its corresponding antibodies. Mb concentration in the sample can be calculated by comparing the calibrator result with same processing.


This assay kit is suitable for automatic or semi - automatic biochemical analyzer with 570nm and 800nm wavelength.

Patient sample testing should be completed within 4 hours. Samples stored at 2 - 8C should be measured within 24 hours. Otherwise, the sample should be stored at - 20C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze - thaw cycles.
This kit comes with a calibrator.

Dry Ice
No
Buffer
Not applicable.
Note
This product is for research use only.
Antigen
Myoglobin (MB)

Hinweis: Die dargestellten Informationen und Dokumente (Bedienungsanleitung, Produktdatenblatt, Sicherheitsdatenblatt und Analysezertifikat) entsprechen unserem letzten Update und sollten lediglich der Orientierung dienen. Wir übernehmen keine Garantie für die Aktualität. Für spezifische Anforderungen bitten wir Sie, uns eine Anfrage zu stellen.

Alle Produkte sind nur für Forschungszwecke bestimmt. Nicht für den menschlichen, tierärztlichen oder therapeutischen Gebrauch.

Menge: Hitachi 7170; R1: 60mlx3 R2: 15mlx3