Human Platelet endothelial cell adhesion molecule (PECAM1) ELISA Kit

Item no. ABK-KTE61255-96T
Manufacturer Abbkine Scientific
Amount 96T
Category
Type Elisa-Kit
Applications ELISA
Specific against Human (Homo sapiens)
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Available
Applications notes
This Human Platelet endothelial cell adhesion molecule (PECAM1) ELISA Kit employs a two-site sandwich ELISA to quantitate PECAM1 in samples. An antibody specific for PECAM1 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and anyPECAM1 present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for PECAM1 is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of PECAM1 bound in the initial step. The color development is stopped and the intensity of the color is measured.
Detection method
Colorimetric
Sample type
Cell culture supernatants#Serum#Plasma#Other biological fluids
Assay type
Sandwich ELISA (quantitative)
Assay duration
Multiple steps standard sandwich ELISA assay with a working time of 3-5 hours. It depends on the experience of the operation person.
Kit components

Human Platelet endothelial cell adhesion molecule microplate
Human Platelet endothelial cell adhesion molecule standard
Human Platelet endothelial cell adhesion molecule detect antibody
Streptavidin-HRP
Standard diluent
Assay buffer
HRP substrate
Stop solution
Wash buffer
Plate covers
Features & Benefits
Human Platelet endothelial cell adhesion molecule (PECAM1) ELISA Kit has high sensitivity and excellent specificity for detection of Human PECAM1. No significant cross-reactivity or interference between Human PECAM1 and analogues was observed.
Usage notes
Do not mix components from different kit lots or use reagents beyond the kit expiration date.
Allow all reagents to warm to room temperature for at least 30 minutes before opening.
Pre-rinse the pipet tip with reagent, use fresh pipet tips for each sample, standard and reagent to avoid contamination.
Unused wells must be kept desiccated at 4 C in the sealed bag provided.
Mix Thoroughly is very important for the result. It is recommended using low frequency oscillator or slight hand shaking every 10 minutes.
It is recommended that all samples and standards be assayed in duplicate or triplicate.
Storage instructions
The unopened kit should be stored at 2 - 8C. After opening, please store refer to protocols.
Shipping
Gel pack with blue ice.
Precautions
The product listed herein is for research use only and is not intended for use in human or clinical diagnosis. Suggested applications of our products are not recommendations to use our products in violation of any patent or as a license. We cannot be responsible for patent infringements or other violations that may occur with the use of this product.
Background
CD31 is a cluster of differentiation molecule. It is also called PECAM-1 for platelet endothelial cell adhesion molecule. It plays a key role in removing aged neutrophils from the body. Macrophages palpate any passing neutrophil and have to decide whether the cell is healthy or has to be ingested. In humans, the gene encoding CD-31 is found on chromosome 17.
If a neutrophil is dying, it will have phosphatidyl serine in its plasma membrane. Both the neutrophil and the macrophage express CD-31 on their membranes, and, during the testing process, these CD-31 molecules bind the two cells together. If the neutrophil is healthy, it will now fire a signal to the macrophage, and the CD-31 molecules will detach. The neutrophil is now free.
Alternative
PECAM1; CD31; FLJ58394; PECAM-1; CD31 antigen; CD31/EndoCAM; PECAM-1; CD31/EndoCAM; adhesion molecule
Accession
P51866

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 96T
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?
 
Close