Comparison

Human Procollagen C-endopeptidase enhancer 2 (PCOLCE2) ELISA Kit

Item no. ABK-KTE61289-96Tx5
Manufacturer Abbkine Scientific
Amount 96Tx5
Category
Type Elisa-Kit
Applications ELISA
Specific against Human (Homo sapiens)
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Available
Applications notes
This Human Procollagen C-endopeptidase enhancer 2 (PCOLCE2) ELISA Kit employs a two-site sandwich ELISA to quantitate PCOLCE2 in samples. An antibody specific for PCOLCE2 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and anyPCOLCE2 present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for PCOLCE2 is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of PCOLCE2 bound in the initial step. The color development is stopped and the intensity of the color is measured.
Detection method
Colorimetric
Sample type
Cell culture supernatants#Serum#Plasma#Other biological fluids
Assay type
Sandwich ELISA (quantitative)
Assay duration
Multiple steps standard sandwich ELISA assay with a working time of 3-5 hours. It depends on the experience of the operation person.
Kit components

Human Procollagen C-endopeptidase enhancer 2 microplate
Human Procollagen C-endopeptidase enhancer 2 standard
Human Procollagen C-endopeptidase enhancer 2 detect antibody
Streptavidin-HRP
Standard diluent
Assay buffer
HRP substrate
Stop solution
Wash buffer
Plate covers
Features & Benefits
Human Procollagen C-endopeptidase enhancer 2 (PCOLCE2) ELISA Kit has high sensitivity and excellent specificity for detection of Human PCOLCE2. No significant cross-reactivity or interference between Human PCOLCE2 and analogues was observed.
Usage notes
Do not mix components from different kit lots or use reagents beyond the kit expiration date.
Allow all reagents to warm to room temperature for at least 30 minutes before opening.
Pre-rinse the pipet tip with reagent, use fresh pipet tips for each sample, standard and reagent to avoid contamination.
Unused wells must be kept desiccated at 4 C in the sealed bag provided.
Mix Thoroughly is very important for the result. It is recommended using low frequency oscillator or slight hand shaking every 10 minutes.
It is recommended that all samples and standards be assayed in duplicate or triplicate.
Storage instructions
The unopened kit should be stored at 2 - 8C. After opening, please store refer to protocols.
Shipping
Gel pack with blue ice.
Precautions
The product listed herein is for research use only and is not intended for use in human or clinical diagnosis. Suggested applications of our products are not recommendations to use our products in violation of any patent or as a license. We cannot be responsible for patent infringements or other violations that may occur with the use of this product.
Background
PCOLCE2 lies 5.2 kb and 102.5 kb centromeric to the transient receptor potential channel-1 (TRPC1) and plastin-1 (PLS1), respectively. The deduced 415-amino acid protein contains an N-terminal signal sequence, 2 CUB domains, and an NTR domain. It also contains a putative myristoylation site, several potential phosphorylation sites, a putative glycosylation site, and an RGD site. PCOLCE2 shares about 43% sequence identity with the PCOLCE protein .
The secreted PCOLCE2 protein is calculated to have a molecular mass of about 47 kD. Northern blot analysis detected ubiquitous expression of a 2-kb transcript, with highest expression in heart, placenta, and trabecular meshwork, and very low expression in brain. Western blot analysis revealed a 52-kD form of PCOLCE2 in human fibroblast cells.
Gene ID
26577
Alternative
PCOLCE2; PCPE2;
Accession
Q9UKZ9

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 96Tx5
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?
 
Close