Comparison

Human Voltage-dependent calcium channel gamma-6 subunit (CACNG6) ELISA Kit

Item no. ABK-KTE62432-48T
Manufacturer Abbkine Scientific
Amount 48T
Category
Type Elisa-Kit
Applications ELISA
Specific against Human (Homo sapiens)
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Available
Applications notes
This Human Voltage-dependent calcium channel gamma-6 subunit (CACNG6) ELISA Kit employs a two-site sandwich ELISA to quantitate CACNG6 in samples. An antibody specific for CACNG6 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and anyCACNG6 present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for CACNG6 is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of CACNG6 bound in the initial step. The color development is stopped and the intensity of the color is measured.
Detection method
Colorimetric
Sample type
Cell culture supernatants#Serum#Plasma#Other biological fluids
Assay type
Sandwich ELISA (quantitative)
Assay duration
Multiple steps standard sandwich ELISA assay with a working time of 3-5 hours. It depends on the experience of the operation person.
Kit components

Human Voltage-dependent calcium channel gamma-6 subunit microplate
Human Voltage-dependent calcium channel gamma-6 subunit standard
Human Voltage-dependent calcium channel gamma-6 subunit detect antibody
Streptavidin-HRP
Standard diluent
Assay buffer
HRP substrate
Stop solution
Wash buffer
Plate covers
Features & Benefits
Human Voltage-dependent calcium channel gamma-6 subunit (CACNG6) ELISA Kit has high sensitivity and excellent specificity for detection of Human CACNG6. No significant cross-reactivity or interference between Human CACNG6 and analogues was observed.
Usage notes
Do not mix components from different kit lots or use reagents beyond the kit expiration date.
Allow all reagents to warm to room temperature for at least 30 minutes before opening.
Pre-rinse the pipet tip with reagent, use fresh pipet tips for each sample, standard and reagent to avoid contamination.
Unused wells must be kept desiccated at 4 C in the sealed bag provided.
Mix Thoroughly is very important for the result. It is recommended using low frequency oscillator or slight hand shaking every 10 minutes.
It is recommended that all samples and standards be assayed in duplicate or triplicate.
Storage instructions
The unopened kit should be stored at 2 - 8C. After opening, please store refer to protocols.
Shipping
Gel pack with blue ice.
Precautions
The product listed herein is for research use only and is not intended for use in human or clinical diagnosis. Suggested applications of our products are not recommendations to use our products in violation of any patent or as a license. We cannot be responsible for patent infringements or other violations that may occur with the use of this product.
Background
CACNg6 represents one of these subunits, gamma, and is one of several gamma subunit proteins. It is an integral membrane protein that is thought to stabilize the calcium channel in an inactive (closed) state. This gene is a member of the neuronal calcium channel gamma subunit gene subfamily of the PMP-22/EMP/MP20 family and is located in a cluster with two similar gamma subunit-encoding genes.The deduced 260-amino acid CACNG6 protein contains 4 transmembrane segments and a highly conserved N-glycosylation site in the first extracellular loop. It has a relatively long N terminus compared with the other CACNG proteins. RT-PCR analysis of 24 adult and fetal tissues detected expression of CACNG6 in all tissues tested except heart, placenta, and colon.
Gene ID
59285
Alternative
CACNG6; Neuronal voltage-gated calcium channel gamma-6 subunit; voltage-dependent calcium channel gamma-6 subunit
Accession
Q9BXT2

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 48T
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?
 
Close