Comparison

EnzyFluoTM Myeloperoxidase Assay Kit

Item no. BAS-EMPO-100
Manufacturer BioAssay Systems
Amount 100 Tests
Quantity options 100 Tests 100x100 Tests 20x100 Tests
Category
Type Assay-Kit
Specific against other
Citations Son, A., et al (2019). Ca2+ influx channel inhibitor saraf protects mice from acute pancreatitis. Gastroenterology, 157(6), 1660-1672.e2. Assay: Myeloperoxidase in mouse tissue.

Hashim, A. A., Helmy, M. M., & Mouneir, S. M. (2018). Cysteinyl leukotrienes predominantly mediate cisplatin-induced acute renal damage in male rats. Journal of Physiology and Pharmacology, 69(5), 779-787. Assay: Myeloperoxidase in rat kidney.

Helmy, M. M., Hashim, A. A., & Mouneir, S. M. (2018). Zileuton alleviates acute cisplatin nephrotoxicity: Inhibition of lipoxygenase pathway favorably modulates the renal oxidative/inflammatory/caspase-3 axis. Prostaglandins & other lipid mediators, 135, 1-10. Assay: Myeloperoxidase in rat tissue.


To find more recent publications, please click here.
ECLASS 10.1 32161090
ECLASS 11.0 32161090
UNSPSC 41116126
Available
Description
MPO peroxidation activity determination in biological samples (e.g. cell lysates, tissues, etc.)
Faqs

What samples have you tested?

The assay kit has been tested in purified myeloperoxidase, tissue and cell samples. Please follow the directions on the protocol for sample pretreatment.

What is the benefit of using a myeloperoxidase inhibitor in the assay?

The provided MPO inhibitor is used to suppress peroxidase activity due to MPO in order to differentiate other peroxidase activities that may be present in the samples. The difference in fluorescence intensities between sample and this sample blank is used to compute enzyme activity specifically due to myeloperoxidase.

I don't have the correct wavelength filter, what other wavelength(s) would work?

The assay can be measured at excitation 500-540 nm and emission at 560-590 nm. Reading outside this range will result in a significant decrease in sensitivity.

Will the assay kit work in a 384 well plate?

Yes, the assay can be used in any standard plate. Simply adjust the sample and reagent volumes accordingly. For 384 well use 20-90 uL final reaction volume.

Can I store unused reagents for future use?

Yes, unused reagents can be stored according to the assay protocol. Repeated freeze/thaw cycles of reagents should be avoided. Working Reagents should be made fresh for each assay and used within 1 hour.

Do I need to use a standard or standard curve with each assay run?

Yes, it is highly recommended run the resorufin standard in each assay.


For more detailed product information and questions, please feel free to Contact Us. Or for more general information regarding our assays, please refer to our General Questions.
Overview

Application

  • MPO peroxidation activity determination in biological samples (e.g. cell lysates, tissues, etc.)

Key Features

  • Fast and sensitive. Linear detection range (20 uL sample): 0.0025 to 2 U/L for 10 min reaction at 25C.
  • Convenient and high-throughput. Homogeneous "mix-incubate-measure" type assay. Can be readily automated on HTS liquid handling systems for processing thousands of samples per day.

Method

  • FL530/585nm

Samples

  • Cell lysates, tissues, etc

Species

  • All

Size

  • 100 tests

Detection Limit

  • 0.0025 U/L

Shelf Life

  • 6 months

More Details

  • MYELOPEROXIDASE (MPO; EC 1.11.2.2) is a peroxidase enzyme and can be found in neutrophil, monocytes, and some soft tissue macrophages. MPO has an ability to use chloride as a cosubstrate with hydrogen peroxide to generate hypochlorous acid, a powerful antimicrobial agent produced by neutrophils. However, an excessive production of hypochlorous acid can lead to oxidative stress and tissues damage. Inflammation may also result when MPO oxidizes various substances such as phenols and anilines. Studies show that increased MPO levels may increase the risk of myocardial infarction and cardiovascular disease.

    BioAssay Systems EnzyFluoTM myeloperoxidase (MPO) assay kit is based on the MPO enzyme reaction with hydrogen peroxide (H2O2) which oxidizes the dye reagent to a highly fluorescent product. The fluorescence intensity of this product, measured at & labda; ex/em = 530/585 nm, is proportional to the total peroxidation activity in the sample. The provided MPO inhibitor is used to suppress peroxidase activity due to MPO in order to differentiate other peroxidase activities that may be present in the samples.

    Related Categories:Oxidative-Stress.htm" target=_blank> Oxidative Stress, Enzyme-Activity-Assays.htm" target=_blank> Enzyme Activity Assays
Shipment
ICE
Storage
-20 C

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 100 Tests
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?
 
Close