Comparison

FGF21 Chemi-Luminescent ELISA Kit (Mouse)

Item no. OKCD03475
Manufacturer AVIVA Systems Biology
Amount 96 Wells
Category
Type Elisa-Kit
Applications CLIA, IA
Specific against Mouse (Murine, Mus musculus)
Sensitivity 15.63 pg/mL
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias Fgf8c;fibroblast growth factor 21;fibroblast growth factor 8c.
Shipping Condition Cool pack
Available
Manufacturer - Type
ELISA Kit
Manufacturer - Category
Root Catalog/Products/ELISA Kits, Root Catalog/Products/Kit
Shipping Temperature
Wet Ice
Gene symbol
Fgf21
Gene Fullname
fibroblast growth factor 21
Reconstitution and storage
2°C to 8°C|-20°C
Description of target
Stimulates glucose uptake in differentiated adipocytes via the induction of glucose transporter SLC2A1/GLUT1 expression (but not SLC2A4/GLUT4 expression). Activity probably requires the presence of KLB.
Nucleotide accession_num
NM_020013
Protein accession_num
NP_064397
Protein name
Fibroblast growth factor 21
Assay info
Assay Methodology: Quantitative Sandwich ELISA
Kit Components
Component: Amount
Fgf21 Microplate: 96 Wells (12 x 8 Well strips)
Fgf21 Lyophilized Standard: 2
100X Fgf21 Biotinylated Detector Anitbody: 1 x 120 uL
100X Avidin-HRP Conjugate: 1 x 120 uL
Standard Diluent: 1 x 20 mL
Detector Antibody Diluent: 1 x 12 mL
Conjugate Diluent: 1 x 12 mL
30X Wash Buffer: 1 x 20 mL
100X Luminol Substrate: 1 x 2 mL
Substrate Diluent: 1 x 20 mL
Kit detection
Chemiluminescent
Kit duration
2h, 40min
Kit linearity
Sample - 1:2 - 1:4 - 1:8 - 1:16
Serum (n=5) - 78-98% - 78-91% - 78-101% - 86-94%
EDTA Plasma (n=5) - 95-104% - 80-92% - 81-88% - 94-101%
Heparin Plasma (n=5) - 95-102% - 78-91% - 92-105% - 80-92%
Kit principle
The microplate provided in this kit has been pre-coated with an antibody specific to Fibroblast Growth Factor 21 (FGF21). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Fibroblast Growth Factor 21 (FGF21). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Fibroblast Growth Factor 21 (FGF21) level in the sample or standard.
Kit recovery
Matrix - Recovery range (%) - Average(%)
Serum (n=5) - 88-96 - 92
EDTA Plasma (n=5) - 79-95 - 80
Heparin Plasma (n=5) - 95-105 - 101
Kit reproducibility
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fibroblast Growth Factor 21 (FGF21) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fibroblast Growth Factor 21 (FGF21) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
Sample Type
Serum, plasma and other biological fluids

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 96 Wells
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?
 
Close