Comparison

XRCC6 Chemi-Luminescent ELISA Kit (Mouse)

Item no. OKCD05535
Manufacturer AVIVA Systems Biology
Amount 96 Wells
Category
Type Elisa-Kit
Applications CLIA, IA
Specific against Mouse (Murine, Mus musculus)
Sensitivity < 4.9pg/mL
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias 5'-deoxyribose-5-phosphate lyase Ku70;5'-dRP/AP lyase Ku70;70kDa;ATP-dependent DNA helicase 2 subunit 1;ATP-dependent DNA helicase II 70 kDa subunit;CTC box-binding factor 75 kDa subunit;CTC75;CTCBF;DNA repair protein XRCC6;G22p;G22p1;ku autoantigen protein p70 homolog;Ku p70;Ku70;thyroid autoantigen 70 kDa;X-ray repair cross-complementing protein 6.
Shipping Condition Cool pack
Available
Manufacturer - Type
ELISA Kit
Manufacturer - Category
Root Catalog/Products/ELISA Kits, Root Catalog/Products/Kit
Shipping Temperature
Wet Ice
Gene symbol
Xrcc6
Gene Fullname
X-ray repair complementing defective repair in Chinese hamster cells 6
Reconstitution and storage
2°C to 8°C|-20°C
Description of target
Single-stranded DNA-dependent ATP-dependent helicase. Has a role in chromosome translocation. The DNA helicase II complex binds preferentially to fork-like ends of double-stranded DNA in a cell cycle-dependent manner. It works in the 3'-5' direction. Binding to DNA may be mediated by XRCC6. Involved in DNA non-homologous end joining (NHEJ) required for double-strand break repair and V(D)J recombination. The XRCC5/6 dimer acts as regulatory subunit of the DNA-dependent protein kinase complex DNA-PK by increasing the affinity of the catalytic subunit PRKDC to DNA by 100-fold. The XRCC5/6 dimer is probably involved in stabilizing broken DNA ends and bringing them together. The assembly of the DNA-PK complex to DNA ends is required for the NHEJ ligation step. Required for osteocalcin gene expression. Probably also acts as a 5'-deoxyribose-5-phosphate lyase (5'-dRP lyase), by catalyzing the beta-elimination of the 5' deoxyribose-5-phosphate at an abasic site near double-strand breaks. 5'-dRP lyase activity allows to 'clean' the termini of abasic sites, a class of nucleotide damage commonly associated with strand breaks, before such broken ends can be joined. The XRCC5/6 dimer together with APEX1 acts as a negative regulator of transcription. Plays a role in the regulation of DNA virus-mediated innate immune response by assembling into the HDP-RNP complex, a complex that serves as a platform for IRF3 phosphorylation and subsequent innate immune response activation through the cGAS-STING pathway (By similarity).
Nucleotide accession_num
NM_010247.2
Protein accession_num
NP_034377.2
Protein name
X-ray repair cross-complementing protein 6
Kit Components
Component: Amount
XRCC6 Microplate: 96 Wells (12 x 8 Well strips)XRCC6 Lyophilized Standard: 2100X XRCC6 HRP-Detector Anitbody: 1 x 120 uL100X Avidin-HRP Conjugate: 1 x 120 uLStandard Diluent: 1 x 20 mLDetector Antibody Diluent: 1 x 12 mLConjugate Diluent: 1 x 12 mL30X Wash Buffer: 1 x 20 mL100X Luminol Substrate: 1 x 9 mLSubstrate Diluent: 1 x 6 mL
Kit detection
Chemiluminescent
Kit duration
2h, 40min
Kit principle
The microplate provided in this kit has been pre-coated with an antibody specific to X-Ray Repair Cross Complementing 6 (XRCC6). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to X-Ray Repair Cross Complementing 6 (XRCC6). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the X-Ray Repair Cross Complementing 6 (XRCC6) level in the sample or standard.
Kit reproducibility
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level X-Ray Repair Cross Complementing 6 (XRCC6) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level X-Ray Repair Cross Complementing 6 (XRCC6) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
Sample Type
Tissue homogenates and other biological fluids

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 96 Wells
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?
 
Close