Comparison

C8G Chemi-Luminescent ELISA Kit (Human)

Item no. OKCD03351
Manufacturer AVIVA Systems Biology
Amount 96 Wells
Category
Type Elisa-Kit
Applications CLIA, IA
Specific against Human (Homo sapiens)
Sensitivity 0.078 ng/mL
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias C8C;complement component 8,gamma polypeptide;complement component C8 gamma chain.
Shipping Condition Cool pack
Available
Manufacturer - Type
ELISA Kit
Manufacturer - Category
Root Catalog/Products/ELISA Kits, Root Catalog/Products/Kit
Shipping Temperature
Wet Ice
Gene symbol
C8G
Gene Fullname
complement C8 gamma chain
Reconstitution and storage
2°C to 8°C|-20°C
Description of target
C8 is a constituent of the membrane attack complex. C8 binds to the C5B-7 complex, forming the C5B-8 complex. C5-B8 binds C9 and acts as a catalyst in the polymerization of C9. The gamma subunit seems to be able to bind retinol.
Nucleotide accession_num
NM_000606
Protein accession_num
NP_000597
Protein name
Complement component C8 gamma chain
Assay info
Assay Methodology: Quantitative Sandwich ELISA
Kit Components
Component: Amount
C8G Microplate: 96 Wells (12 x 8 Well strips)
C8G Lyophilized Standard: 2
100X C8G Biotinylated Detector Anitbody: 1 x 120 uL
100X Avidin-HRP Conjugate: 1 x 120 uL
Standard Diluent: 1 x 20 mL
Detector Antibody Diluent: 1 x 12 mL
Conjugate Diluent: 1 x 12 mL
30X Wash Buffer: 1 x 20 mL
100X Luminol Substrate: 1 x 2 mL
Substrate Diluent: 1 x 20 mL
Kit detection
Chemiluminescent
Kit duration
2h, 40min
Kit linearity
Sample - 1:2 - 1:4 - 1:8 - 1:16
Serum (n=5) - 92-99% - 78-90% - 93-101% - 79-101%
EDTA Plasma (n=5) - 82-101% - 90-99% - 91-105% - 83-96%
Heparin Plasma (n=5) - 98-105% - 92-99% - 97-105% - 80-101%
Kit principle
The microplate provided in this kit has been pre-coated with an antibody specific to Complement Component 8g (C8g). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Complement Component 8g (C8g). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Complement Component 8g (C8g) level in the sample or standard.
Kit recovery
Matrix - Recovery range (%) - Average(%)
Serum (n=5) - 96-104 - 101
EDTA Plasma (n=5) - 85-101 - 96
Heparin Plasma (n=5) - 83-103 - 93
Kit reproducibility
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Complement Component 8g (C8g) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Complement Component 8g (C8g) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10% Inter-Assay: CV<12%
Sample Type
Serum, plasma and other biological fluids

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 96 Wells
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?
 
Close