Comparison

Toxoplasma IgG Enzyme Immunoassay Test Kit

Item no. 40-052-115029
Manufacturer GENWAY
Amount 1ea
Category
Type Elisa-Kit
Specific against other
ECLASS 10.1 32160605
ECLASS 11.0 32160605
UNSPSC 41116126
Alias GWB-789E36
Similar products 40-052-115029
Available
Genway ID:
GWB-789E36
Product Name:
IGG Antibodies to Toxoplasma gondiiSample Type: Serum# of Samples: 1X96 Assays
Intended Use: The Biotech Toxoplasma IgG ELISA is intended for use in evaluating serologic status to Toxoplasma gondii infection. Introduction: Toxoplasmosis is caused by the intracellular parasite Toxoplasma gondii and may be contracted by consuming contaminated meat or by coming in contact with cat feces containing oocysts. In adolescence and adulthood most infections are subclinical. However if a pregnant woman contracts toxoplasmosis it may be passed through the placenta to the fetus resulting in congenital toxoplasmosis which is a cause of mortality and malformation. Asymptomatic infants may develop abnormalities later in life. Principle of the test: Purified Toxoplasma gondii antigen is coated on the surface of microwells. Diluted serum is added to the wells and the Toxoplasma gondii IgG-specific antibody if present binds to the antigen. All unbound materials are washed away. HRP-conjugate is added which binds to the antibody-antigen complex. Excess HRP-conjugate is washed off and a solution of TMB Reagent is added. The enzyme conjugate catalytic reaction is stopped at a specific time. The intensity of the color generated is proportional to the amount of IgG-specific antibody in the sample. The results are read by a microwell reader compared in a parallel manner with calibrator and controls. Limitation of the Test: 1. Reliable and reproducible results will be obtained when the assay procedure is carried out with a complete understandingof the package insert instructions and with adherence to good laboratory practice. 2. The wash procedure is critical. Insufficient washing will result in poor precision and falsely elevated absorbance readings. 3. Serum samples demonstrating gross lipemia gross hemolysis or turbidity should not be used with this test. Precision: A study was performed to document typical assay precision with the Biotech Toxo IgG EIA product. The mean SD and %CV were calculated for Intra- and Inter-Assay in concentration value (IU/mL).
Product Name:
IGG Antibodies to Toxoplasma gondii
Subcellular Location:
Secreted.
Disease:
Chromosomal aberrations involving IGHG1 may be a cause of multiple myeloma [MIM:254500]. Translocation t(11; 14)(q13; q32) with CCND1; translocation t(4; 14)(p16. 3; q32. 3) with FGFR3; translocation t(6; 14)(p25; q32) with IRF4.
Miscellaneous:
Nie has the G1M(17) allotypic marker 97-K and the G1M(1) markers 239-D and 241-L. KOL and EU sequences have the G1M(3) marker and the G1M (non-1) markers.
Miscellaneous:
Nie also differs in the amidation states of 35 116 198 269 and 272.
Miscellaneous:
EU also differs in the amidation states of residues 155 166 177 195 198 269 and 272 and in the order of residues 268-272.
Miscellaneous:
KOL also differs in the amidation states of residues 198 267 and 272.

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 1ea
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?
 
Close