Comparison

QuantiQuik™ Urea (BUN) Quick Test Strips

Item no. BAS-QQUREA10
Manufacturer BioAssay Systems
Amount 10 Tests
Quantity options 10 Tests 100 x 10 Tests 20 x 10 Tests
Category
Type Rapid-Test
Specific against other
Citations Zhang, X., Guo, K., Xia, F., Zhao, X., Huang, Z., & Niu, J. (2018). FGF23 C-tail improves diabetic nephropathy by attenuating renal fibrosis and inflammation. BMC biotechnology, 18(1), 33. Assay: Ureain mouse urine.


To find more recent publications, please click here.
ECLASS 10.1 42021690
ECLASS 11.0 42021690
UNSPSC 41116205
Shipping Condition Room temperature
Available
Shipping Temperature
RT
Storage Conditions
RT
Description
For rapid, direct determination of urea concentrations in food and beverage samples as well as biological samples. Key Features: Fast and sensitive. Use of 20 µ L sample. Semi-quantitative measurement between 0-1500 mg/L (undiluted) urea. Convenient. No expensive plate or cuvette readers needed. Sample treatment and assay can be performed in under 15 minutes. Method: Visual. Samples: Serum, plasma, urine, etc. Species: All. Procedure: Assay takes approximately 15 min. Kit size: 10 tests.
FAQs
What samples have you tested?
The strips have been tested on serum, plasma, urine, and milk samples.

My sample turns the strip very dark pink, how can I determine the urea concentration?
Very dark pink indicates that the diluted sample concentration is greater than 1500 mg/L Urea. To obtain a more accurate concentration, the sample should be further diluted and retested. For example, if the sample was tested undiluted, try diluting 5x or 10x.

I don’t have access to a pipetteman. How can I accurately measure out my samples?
We offer exact volume transfer pipettes as an accessory. For samples requiring a 2x dilution, order the 20 uL transfer pipettes (TP20). For samples requiring a 31x dilution, order the 300 uL transfer pipettes (TP300) and the 20 uL transfer pipettes (TP20).

Can I store unused reagents for future use?
Yes, unused reagents can be stored according to the assay protocol. The strips should be kept in a dry, cool location and protected from light.

The strip did not change color even though I know there is urea present in my sample. What is going on?
If the strip is still yellow, but is known to have urea present in it, this could mean that the sample was diluted too much and no longer can be detected by the strips. Another possibility is that something in the sample is interfering with the strip reaction. Samples that are very acidic may interfere with the strip reaction and should be greatly diluted or avoided if possible.


For more detailed product information and questions, please feel free to send an inquiry to info@hoelzel.de
Overview
Application: Direct determination of urea concentrations in food and beverage samples as well as biological samples.
Note: Requires access to pipettes and deionized water for dilution. 20 uL Transfer Pipettes (Catalog: TP-20), 300 uL Transfer Pipettes (Catalog: TP-300) and Deionized Water (Catalog: DH2O-010) can also be purchased separately.
Key Features: Fast and sensitive. Use of 20 uL sample. Semi-quantitative measurement between 0-1500 mg/L (undiluted) urea.
Convenient. No expensive plate or cuvette readers needed.
Sample treatment and assay can be performed in under 15 minutes.
Method: Visual
Samples: Serum, plasma, urine, etc
Species: All
Size: 10 tests
Shelf Life: 6 months
More Details: UREA, the major end product of protein catabolism in animals, is primarily produced in the liver and secreted by the kidneys. It is the primary vehicle for removal of toxic ammonia from the body. Urea is widely used in the agricultural industry as a fertilizer as well as an animal feed additive. Milk urea is often monitored to determine the amount of protein in an animal’s diet. Additionally, small amounts of urea can be found in many kinds of fermented foods and beverages.

BioAssay Systems QuantiQuik Urea (BUN) Test Strips are based on Urease catalyzed conversion of urea to ammonium and carbon dioxide. The pH of the reaction medium is monitored by a chromogen and the intensity of the product color is directly proportional to the urea concentration in the sample. The QuantiQuik Urea Test strips allow for rapid and inexpensive quantitative determination of urea or blood urea nitrogen (BUN) and do not require sophisticated laboratory instruments.
Shelf life (Months)
18

Note: The presented information and documents (Manual, Product Datasheet, Safety Datasheet and Certificate of Analysis) correspond to our latest update and should serve for orientational purpose only. We do not guarantee the topicality. We would kindly ask you to make a request for specific requirements, if necessary.

All products are intended for research use only (RUO). Not for human, veterinary or therapeutic use.

Amount: 10 Tests
Available: In stock
available

Compare

Add to wishlist

Get an offer

Request delivery time

Ask a technical question

Submit a bulk request

Questions about this Product?